Setting Temperature Controllers
Setting Temperature Controllers
Setting Temperature Controllers
Setting Temperature Controllers
To change temperature of the material, oil or heated hose, use the (A) button. To
change the temperature on when the material pump or agitator engages, use the (C)
button.
1)
Press and hold set button (A) for 5 sec. Light (B) will turn on while in the set-
ting mode.
2)
Press "UP" or "DOWN" button until desired temp is shown.
3)
Press set button (A) , light (B) will turn off and the readout will display actual
temperature.
4)
Indicator light (B) will remain on anytime the burner is running.
NOTE: Press set button (A) at anytime to display the setpoint temperature.
For safety, the high limit settings are locked in at the factory to prevent overheating.
The settings are:
Oil Controller- 550º F (288º C)
Material Controller- 450º F (232º C)
Heated Hose Controller- 400º F (218º C)
These settings can be field adjusted
for specific applications.
Consult the factory for instruc-
tions.
"PFo" indicates broken or absent probe.
"PFc" indicates short circuited probe.