- 20 -
Agitation Start-up
Loading Empty Tank
1)
Start agitation by rotating knob (A) counterclockwise.
2)
Tank outlet valve must be in the "off" position.
3)
All material must be clean. Keep all foreign matter out of melting tank.
4)
Open the material door (1) and place slab or biscuit (2) on the open door against the
holder (3).
5)
Push door to the closed position.
DO NOT DROP MATERIAL INTO THE MELTER
WITH DOOR OPEN.
3
1
2
A
B
Material Left in Tank
1)
When oil reaches 250º F., rotate knob (A) counterclockwise and observe pressure
gauge (B). If the gauge jumps to 1000-1200 psi and remains there with no fluctuation,
the agitator is not turning. The oil is going over the relief valve setting. Place knob into
neutral position and wait until sufficient melting occurs. (On Model 230 and 410, gauge
will vary between 750 - 850 PSI).