- 22 -
Sealing Procedure
A
C
B
D
SEALING HOSE
HOSE
ACCESS PORT
HOLDER
WAND
BOOM
F
Diagram 12
1)
*Turn wand valve (A) "off" and remove the wand from the access port until you can see
the sealing tip.
2)
Open wand valve to the full "on" position and observe the material as it flows into the
tank through the access port.
3)
Adjust the pressure valve (B) until the flow rate appears to be correct for the size crack
or joint to be filled.
4)
Turn the wand valve "off" and proceed to the crack or joint to be filled.
5)
Place the sealing tip into the joint, open the wand valve to the full "on" position and
begin sealing by dragging tip through the joint.
6)
If the flow rate is incorrect, repeat steps 1 through 3 until the desired flow is achieved.
7)
As you approach the end of the joint, turn the wand valve "off" to avoid excess spillage.
8)
To avoid material freezing in the hose, always return the wand to the access port and
open the wand valve to allow material to circulate through the hose.
NOTE: On units equipped with the electrically heated hose option, the wand can be
placed in the wand holder instead of the access port.
*Does not apply to remote wand model.
Summary of Contents for MAGMA 110
Page 48: ... 48 Wiring Diagrams Refer to Individual Wiring Diagrams for Details ...
Page 49: ... 49 Wiring Diagrams Trailer Wiring Diagram ...
Page 50: ... 50 Engine and Burner Wiring Harness Wiring Diagrams ...
Page 51: ... 51 Wiring Diagrams Relay Panel ...
Page 52: ... 52 Wiring Diagrams Temperature Control Wiring Diagram ...
Page 53: ... 53 Wiring Diagrams Primary Control ...
Page 54: ... 54 Wiring Diagrams LOFA Engine Shutdown Heated Hose Generator ...
Page 59: ... 59 Plumbing System Parts List Dual Wand Single Wand ...
Page 75: ... 75 11 12 Miscellaneous Parts ...
Page 77: ... 77 ...
Page 78: ...2601 Niagara Lane Plymouth MN 55447 763 557 1982 800 328 3874 Fax 763 557 1971 ...