- 27
-
Material System Cleanout
FLUSHING REHEATABLE MATERIALS (Solvent Tank Option)
To save material, proceed through the five steps of the Reverse Flow Cleanout Method and
then:
1)
Remove wand from access port and place end into waste container.
2)
Open sealing hose valve and wand valve.
3)
Connect solvent tank hose to air cleanout connection and open solvent tank flow valve.
4)
Open air cleanout valve and allow 4-5 gallons of solvent to flow into the plumbing sys-
tem.
5)
As the solvent is filling the system, turn the material pump to the normal flow position by
rotating knob counterclockwise.
6)
The solvent will flush the system and empty into the waste container.
7)
Turn "off" the solvent tank flow valve and the air cleanout valve. Return the material
pump knob to the neutral position.
8)
Remove the sealing hose from the hose holder and drain as much solvent from the
hose as possible (Non-heated hose models only).
9)
Close sealing hose valve, wand valve and open pressure valve.
10)
Reuse the solvent if possible or dispose of it according to EPA guidelines.
Summary of Contents for MAGMA 110
Page 48: ... 48 Wiring Diagrams Refer to Individual Wiring Diagrams for Details ...
Page 49: ... 49 Wiring Diagrams Trailer Wiring Diagram ...
Page 50: ... 50 Engine and Burner Wiring Harness Wiring Diagrams ...
Page 51: ... 51 Wiring Diagrams Relay Panel ...
Page 52: ... 52 Wiring Diagrams Temperature Control Wiring Diagram ...
Page 53: ... 53 Wiring Diagrams Primary Control ...
Page 54: ... 54 Wiring Diagrams LOFA Engine Shutdown Heated Hose Generator ...
Page 59: ... 59 Plumbing System Parts List Dual Wand Single Wand ...
Page 75: ... 75 11 12 Miscellaneous Parts ...
Page 77: ... 77 ...
Page 78: ...2601 Niagara Lane Plymouth MN 55447 763 557 1982 800 328 3874 Fax 763 557 1971 ...