- 16 -
Automatic Temperature Control Setting
NOTE: On diesel units, the engine must be running before activating temperature
control. The automatic temperature control system monitors the heat transfer
oil temperature and material temperature (Refer to diagram 11).
1)
Set the oil controller (A) to 550º F (See Setting Temperature Controllers, pg. 17)
2)
Set the material controller (B) to the recommended material working temperature which
is typically listed on the material container.
3)
On units with heated hose, set the hose controller (C) to the pour temperature.
4)
Turn rocker switch (D) on. The switch will light up to indicate that the control system is
activated. The oil control indicator (F) will light also. The material control light (G) will
be on only when burner is running. Lights (D,F and G) should light during a cold start
up.
5)
Turn switch (H) on to activate the heated hose (if equipped). The switch will light up to
indicate power is on.
6)
Hose indicator light (J) will light only when hose is being heated.
7)
Switch (E) is used to activate remote control sealing wand valve (if equipped).
8)
Switch (I) is used to activate any optional accessories.
A
B
C
F
D
H
I
G
J
E
Diagram 11
Summary of Contents for MAGMA 110
Page 48: ... 48 Wiring Diagrams Refer to Individual Wiring Diagrams for Details ...
Page 49: ... 49 Wiring Diagrams Trailer Wiring Diagram ...
Page 50: ... 50 Engine and Burner Wiring Harness Wiring Diagrams ...
Page 51: ... 51 Wiring Diagrams Relay Panel ...
Page 52: ... 52 Wiring Diagrams Temperature Control Wiring Diagram ...
Page 53: ... 53 Wiring Diagrams Primary Control ...
Page 54: ... 54 Wiring Diagrams LOFA Engine Shutdown Heated Hose Generator ...
Page 59: ... 59 Plumbing System Parts List Dual Wand Single Wand ...
Page 75: ... 75 11 12 Miscellaneous Parts ...
Page 77: ... 77 ...
Page 78: ...2601 Niagara Lane Plymouth MN 55447 763 557 1982 800 328 3874 Fax 763 557 1971 ...