Setting Temperature Controllers
1)
Press set button (A). Light (B) will flash while in the setting mode.
2)
Press "UP" or "DOWN" button until desired temp is shown.
3)
After a few seconds, light (B) will quit flashing and the readout will display actual
temperature.
4)
Indicator light (B) will remain on anytime the burner is running.
A
B
Increase (UP)
Decrease (DOWN)
NOTE: Press set button (A) at anytime to display the setpoint temperature.
For safety, the high limit settings are locked in at the factory to prevent overheating. The
settings are:
Oil Controller- 575 Degrees Fahrenheit
Material Controller- 450 Degrees Fahrenheit
Heated Hose Controller- 425 Degrees Fahrenheit
These settings can be field adjusted for specific applications.
Consult the factory for instructions.
Setting your controllers higher than the high limit will cause an error code as shown below.
Troubleshooting Codes
"EEE" indicates thermocouple break, no sensor,
or overrange of system.
"---" indicates shorted thermocouple.
Summary of Contents for MAGMA 110
Page 48: ... 48 Wiring Diagrams Refer to Individual Wiring Diagrams for Details ...
Page 49: ... 49 Wiring Diagrams Trailer Wiring Diagram ...
Page 50: ... 50 Engine and Burner Wiring Harness Wiring Diagrams ...
Page 51: ... 51 Wiring Diagrams Relay Panel ...
Page 52: ... 52 Wiring Diagrams Temperature Control Wiring Diagram ...
Page 53: ... 53 Wiring Diagrams Primary Control ...
Page 54: ... 54 Wiring Diagrams LOFA Engine Shutdown Heated Hose Generator ...
Page 59: ... 59 Plumbing System Parts List Dual Wand Single Wand ...
Page 75: ... 75 11 12 Miscellaneous Parts ...
Page 77: ... 77 ...
Page 78: ...2601 Niagara Lane Plymouth MN 55447 763 557 1982 800 328 3874 Fax 763 557 1971 ...