background image

Summary of Contents for LE-310

Page 1: ......

Page 2: ...pressed or implied Ciena Corporation will not be liable for any damages of any kind arising from the use of this User Guide including but not limited to direct indirect incidental punitive and consequ...

Page 3: ...g the reproduction modification distribution transmission republication display or performance of the content in this User Guide is strictly prohibited Trademarks Ciena Corporation trademarks may not...

Page 4: ...may take a long period of time before it is finalized thus pending trademarks service marks and tradenames may be in use by the corporation Trademarks service marks and tradenames must be used with t...

Page 5: ...LE 3xx LE 4xx Hardware Installation User Guide ISO Compliance...

Page 6: ...stningen f r endast ske av utbildad servicepersonal WAARSCHUWING Deze apparatuur mag alleen door gekwalificeerd servicepersoneel worden ge nstalleerd en onderhouden ADVARSEL Dette utstyret skal kun in...

Page 7: ...ement 7 Prioritization 7 IGMP 8 Power and Redundancy 8 Link Aggregation 8 Hardware Description 9 LE 310 10 LE 311 LE 311v 10 LE 327 11 LE 427 12 1000BASE X Uplink Ports 12 10 100BASE TX Subscriber Por...

Page 8: ...r Consumption 48 SNMP Traps 50 Console Port Pin Assignments 51 Appendix B Regulatory Compliance and Safety 53 Class 1 Laser Product 53 Radiation from Open Port Aperture 55 EU Declaration of Conformity...

Page 9: ...LE 3xx LE 4xx Hardware Installation User Guide iii E mail Address 81 Telephone and Fax 82 Glossary...

Page 10: ...iv LE 3xx LE 4xx Hardware Installation User Guide...

Page 11: ...r users such as network technicians and system administrators who will install these devices into a services distribution infrastructure It assumes that the intended users possess basic knowledge of b...

Page 12: ...ntained alongside a symbol corresponds to one of three levels WARNING This symbol is used to highlight information so the user can avoid personal injury CAUTION This symbol is used to highlight inform...

Page 13: ...r network The LE 4xx SCS includes 16 10 100 Mbps RJ 45 Ethernet ports for subscriber connections It also provides 2 dual speed 100BASE FX 1000BASE X SFP uplink ports A 10 100 Mbps RJ 45 and DB 9 RS 23...

Page 14: ...for interconnection within the provider s network only Connection to multiple providers networks or the PSTN can be achieved using other solutions that are available within the Ciena World Wide Packet...

Page 15: ...ov skupiny Ciena World Wide Packets CUIDADO As portas do assinante em todos os dispositivos LE 3xx SCS SDS e LE 4xx SCS destinam se somente interconex o dentro da rede do provedor A conex o a m ltipla...

Page 16: ...vices can be provisioned in real time without requiring software reloads or network outages Alarms are also managed using NMS Refer to the LightningEdge Network Supervisor EMS and NMS manuals for more...

Page 17: ...in turn can trigger SNMP traps or other elements VLAN Management Provisioning and maintaining VLANs is fast and easy using the Device Manager Each VLAN is established with its own traffic rate and bil...

Page 18: ...eams without user intervention Power and Redundancy The LE 310 is only available as an AC powered device The LE 311 LE 311v LE 327 and LE 427 feature hot swappable power supplies One power supply is r...

Page 19: ...11v and LE 327 are designed to aggregate up to 24 100 Mbps subscriber connections using IEEE 802 3u Ethernet Table 1 1 The 3xx SCS SDS Family of Products Model Interfaces Location of Connectors Rack U...

Page 20: ...status LEDs for the 3 SFP 100 1000 Mbps uplink ports are located to the right of each port Status LEDs for the 10 100 100BASE TX port and the management port are integrated into the port itself Figure...

Page 21: ...1 RU dimension as most of the other devices Status LEDs for the 100 Mbps ports are located immediately above or below each port depending upon the port while the status LEDs for the Gigabit ports are...

Page 22: ...ng compliant optics to be plugged in to change the external interface of the port thus providing a mix of possible distances and media types 10 100BASE TX Subscriber Ports LE 311 LE 311v and LE 327 Th...

Page 23: ...d management The RS 232 port connector utilizes a standard DB 9 connector that follows standard DTE wiring pin assignment A null modem cable should be used to connect a PC DTE to the device console po...

Page 24: ...red off or the reset button is pressed System is shutting down because the reset button was pressed STATUS Solid Green Blinking Green Indicates status normal system ready or a non fatal error if the A...

Page 25: ...ports The LE 327 has the LEDs above the ports in the top row and below the individual ports in the bottom row These port LEDs indicate the status of each of the 100 Mbps subscriber ports For convenien...

Page 26: ...port has two LEDs associated with it These are located at the top of the port These LEDs indicate the port s status Figure 1 7 100BASE TX status LEDs Power Supply The AC power supply for all models e...

Page 27: ...figuration If the device does not have an operation configuration the default configuration will be utilized Local Management Port The local management port has a default IP address of 172 16 233 214...

Page 28: ...18 LE 3xx LE 4xx Hardware Installation User Guide DEFAULT CONFIGURATION...

Page 29: ...isually inspect all parts for damage The following items are shipped with the SCS SDS Power cable Mounting Brackets Rack Ears and screws Self adhesive rubber feet desktop installation SCS SDS Installa...

Page 30: ...voedingsbron aansluit ADVARSEL Les alle installasjonsinstruksjonene f r du kobler LighteningEdge innretninger til en str mkilde Italian leggere le istruzioni di installazione prima di collegare i dis...

Page 31: ...eren Sie den Schalthebel des Trennschalters mit Klebeband in der AUS Position um ein versehentliches Einschalten zu vermeiden AVERTISSEMENT Avant d effectuer la proc dure assurez vous de la mise hors...

Page 32: ...o polohy OFF VYP Rukov prep na a isti a pripevnite p skou v polohe OFF VYP aby ste predi li n hodn mu uzavretiu okruhu Portuguese Antes de executar o procedimento assegure se de que n o haja fornecime...

Page 33: ...or 4 Plug the J 9 slotted connector into the rear of the device making sure that it is completely seated 5 Restore power to the input DC circuit 6 Verify that the PWR LED on the front of the device is...

Page 34: ...by connecting each power supply to a separate input circuit In the event of a power failure on the first source the second source may still be available Power supplies are hot swappable allowing one...

Page 35: ...o sistema est em opera o Power Cord and Power Cord Restraints CAUTION All AC power cords must meet the requirements of the local and national electric codes prior to installation VORSICHT Alle Netzka...

Page 36: ...iner is snapped into the fan outlet grid For devices with removable power supplies a twistable cord retainer is used Contact Ciena World Wide Packets Sales to purchase these retainer clips Power Cord...

Page 37: ...ly provides one green LED to indicate the status of the power supply The LED will be on when the power supply is on and receiving source power If the source power exceeds or drops below allowable tole...

Page 38: ...voorkomen ADVARSEL For forebygge NAS skade p elektroniske komponenter bruk alltid en NAS stropp n r du h ndterer moduler eller kommer i kontakt med interne komponenter av SDS SCS Italian al fine di i...

Page 39: ...tion um ein versehentliches Einschalten zu vermeiden AVERTISSEMENT Avant d effectuer la proc dure assurez vous de la mise hors tension compl te du circuit en courant continu Mettez en position OFF le...

Page 40: ...uguese Antes de executar o procedimento assegure se de que n o haja fornecimento de energia no circuito de CC Localize o interruptor de circuito no painel que alimenta o circuito de CC e coloque o na...

Page 41: ...are che non vi siano fili volanti sul conduttore di ingresso che possano entrare a contatto con altre parti della morsettiera UPOZORNENIE Pri prip jan svorkovn c sa presved te e zat lan pr dy pr vodn...

Page 42: ...SEL F r denne prosedyren utf res sjekk at all nettstr m til DC kretsen er frakoblet Lokaliser den sikringen p brytertavla som betjener den aktuelle DC kretsen og sett bryteren i AV stilling Sett en ta...

Page 43: ...t media types One pluggable optic module can be installed into each available slot Optic modules can be hot swapped The following figure shows a typical pluggable optic module and its parts Figure 2 6...

Page 44: ...e optische werking aan de hand van de statuslampjes Kijk niet in de laser om te zien of de eenheid goed functioneert Raadpleeg voor meer veiligheidsinformatie over lasers bijlage B Naleving van wetgev...

Page 45: ...e or any other type of tape to secure cables Overstress cables by over tightening cable ties or stapling cables to the point where crushing is visible This is particularly applicable for fiber optic c...

Page 46: ...If additional information on configuring an IP address is needed contact Customer Support NOTE If the device has not been assigned an IP address other than the default IP address either manually or t...

Page 47: ...nde Hvis det legges inn informasjon som ikke overensstemmer med nettverksinnstillingene er kommunikasjon med enheten kanskje ikke lenger mulig Hvis alle andre feils kingsmetoder er pr vd kan det v re...

Page 48: ...38 LE 3xx LE 4xx Hardware Installation User Guide INITIAL CONFIGURATION...

Page 49: ...Error Conditions PWR STATUS ALARM LEDs Indication Unit Action POST1 OFF OFF OFF Boot up failure Flash is corrupted or cannot be accessed Unit is unable to boot LEDs are in default state ON OFF 1 blink...

Page 50: ...t ON ON 4 blinks Switch cannot access packet storage RAM to store packets Unit will log error then reboot ON ON 5 blinks EEPROM checksum failed No MAC address present Unit will log error then reboot O...

Page 51: ...tch panel verify that the connectors are properly installed 3 If link is still not established inspect cables to ensure that they have not been damaged 4 If the above steps are successfully completed...

Page 52: ...eset it and check the device for power restoration 10 If breaker is tripped again disconnect the unit and reset the breaker to verify whether or not the device is the cause If it is not the cause cont...

Page 53: ...power cable back into the wall outlet 15 Verify that the power cables are properly attached to the device 16 If the unit still does not boot the Status LED remains off or continues blinking follow th...

Page 54: ...e UNIQUEMENT une fois que toutes les autres mesures de d pannage ont t appliqu es et n ont pas permis de r soudre le probl me L activation du bouton Reset r amorce l unit centrale de l appareil La m...

Page 55: ...aplicativos e configura o apagada O dispositivo volta s configura es padr o de f brica Reset CPU Flash Two types of resets can be performed using the Reset button a Shutdown Reboot or a Reset to Facto...

Page 56: ...gement port 2 Carefully insert the end of a large straightened paperclip or a similar object with a blunt end into the reset button hole and gently depress and hold the RESET button inside the hole fo...

Page 57: ...put Power LE 310 100 240 VAC All others 85 264 VAC 47 63 Hz Amps LE 310 0 6 0 3 LE 311 311v 0 9 1 4 LE 327 0 45 1 0 Amps 72 VDC to 38 VDC 1 40 9 2 31 5 Amps DC devices only LE 310 63 Watts All others...

Page 58: ...t running BTU hr Calculation Watts 3 4129 Standard MIB Support SNMP MIB II RFC 1213 Bridge MIB RFC 1493 MIB II interfaces RFC 1573 RMON MIB RFC 1757 RMON II RFC 2021 Ethernet like Interface MIB RFC 16...

Page 59: ...AC Watts 90 120 240 90 120 240 LE 310 Min Load 0 4 0 4 0 2 39 6 43 2 50 4 Max Load 0 5 0 4 0 24 45 0 48 0 57 6 LE 311 311v Min Load 0 6 0 5 0 2 55 8 55 2 57 6 Max Load 0 7 0 5 0 3 63 9 63 6 64 8 LE 32...

Page 60: ...dcast packets received exceeds configured packet limit wwpPvstBpduReceived WWP Sent when Per VLAN Spanning Tree PVST BPDU is received wwpEnvPowerSupplyStatusNotification WWP Device power supply state...

Page 61: ...nt of the device uses a common 9 pin D type connector for attachment The DB 9 connector on the device is a male connector The cord used to connect to the device should be a standard null modem cable w...

Page 62: ...52 LE 3xx LE 4xx Hardware Installation User Guide CONSOLE PORT PIN ASSIGNMENTS...

Page 63: ...ne Lasereinrichtung der Klasse 1 AVERTISSEMENT Produit laser de classe 1 VARNING Laserprodukt Klass 1 Table B 1 Regulatory Approval Declarations Issue Approval Declaration Safety UL 60950 1 2003 First...

Page 64: ...r les quipements de technologie de l information et les normes europ ennes EN60825 1 et EN60825 2 Les metteurs r cepteurs ne r pondant pas ces normes peuvent provoquer des affections oculaires chez le...

Page 65: ...e normy EN60825 1 a EN60825 2 Nepou vanie laserov ch vysiela ov a prij ma ov sp aj cich tieto normy by mohlo sp sobi po kodenie zraku u vatel ov alebo servisn ho person lu ktor pracuje v bl zkosti zar...

Page 66: ...e dall apertura della porta quando non collegato un cavo in fibra evitare l esposizione alle radiazioni e non osservare mai direttamente le aperture libere UPOZORNENIE Vyhnite sa vystaveniu iarenia a...

Page 67: ...radiao de classe B B Ethernet FCC Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following conditions This device may not cause harmful interference This devi...

Page 68: ...tenne ndern Den Standort des Ger ts in Bezug zum Empf nger ver ndern Das Ger t vom Empf nger weg bewegen Das Ger t an einer anderen Steckdose anschlie en so dass der Empf nger und das Ger t an verschi...

Page 69: ...helpen met de volgende maatregelen Verander de stand van de ontvangstantenne Verplaats het apparaaat ten opzichte van de ontvanger Zet het apparaat verder van de ontvanger af Steek de stekker van het...

Page 70: ...oto zariadenie sp sobuje ru enie r diov ho alebo telev zneho pr jmu u vatel by mal sk sit opravit ru enie nasledovn mi opatreniami Preorientujte prij maciu ant nu Premiestnite zariadenie v ohl adom na...

Page 71: ...L apparecchiatura deve accettare tutte le interferenze ricevute anche se possono provocarne un funzionamento indesiderato Nel caso in cui l apparecchiatura dovesse provocare interferenze dannose alla...

Page 72: ...aux appareils de la classe B prescrites par le r glement de brouillage radio lectrique dict par le Minist re des Communications du Canada CE Compliance The CE mark on the chassis of SCS units signifi...

Page 73: ...p alla LE 3xx SCS SDS och LE 4xx SCS enheter r endast avsedda f r hopkoppling inom leverant rens n tverk Anslutning till flera leverant rers n tverk eller det publika telefonn tet PTN kan uppn s med...

Page 74: ...SCS SDS verwendeten Warnhinweise erl utert WARNING This warning note means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involve...

Page 75: ...ed v konom pr ce na niektorom zo zariaden si uvedomte rizik spojen s elektrick mi obvodmi a obozn mte sa s be n mi postupmi na zamedzenie neh d ADVERT NCIA Esta nota de advert ncia significa perigo Vo...

Page 76: ...beit an Ger ten die an das Stromnetz angeschlossen sind alle Schmuckst cke einschlie lich Ringe Ketten und Uhren ab Metallgegenst nde erhitzen sich beim Strom und Erdungsanschluss Dies kann schwerwieg...

Page 77: ...niny resp kovov predmety sa m u privari k svork m ADVERT NCIA Antes de trabalhar com equipamento conectado a linhas de alimenta o tire suas j ias e acess rios incluindo an is cord es e rel gios Objeto...

Page 78: ...nneer u deze eenheid installeert moet u alle stroomkabels stevig bevestigen om de aansluitingen van de veldbekabeling niet te ontregelen ADVARSEL Sikre all str mkabling n r denne enheten installeres f...

Page 79: ...sbeugels zijn uitsluitend berekend op het gewicht van de eenheid Als de beugels ten gevolge van overgewicht losraken kan dat lichamelijk letsel en beschadiging van de apparatuur veroorzaken ADVARSEL N...

Page 80: ...all power is off locate the circuit breaker on the panel board that services the DC circuit s switch the circuit breaker s to the OFF position and tape the switch handle of the circuit breaker s in th...

Page 81: ...guire una procedura di manutenzione assicurarsi che l alimentazione dell unit sia spenta Per unit CA disinserire il cavo di alimentazione Per unit CC verificare che l alimentazione sia spenta individu...

Page 82: ...o posledn ADVERT NCIA Ao instalar ou executar manuten o na unidade a conex o com o terra deve sempre ser feita primeiro e desfeita por ltimo DC Power Warnings WARNING Readily accessible and appropriat...

Page 83: ...imentazione CC dell edificio e questa apparecchiatura Affidare l installazione di interruttori e conduttori unicamente al personale di assistenza qualificato nel rispetto dei codici elettrici regional...

Page 84: ...nergiu presunut m rukov te isti a do polohy ON ZAP ADVERT NCIA Ap s conectar os cabos da fonte de alimenta o de CC retire a fita adesiva do interruptor de circuito e volte a fornecer alimenta o coloca...

Page 85: ...rk on the system or connect or disconnect cables during periods of lightning activity WARNUNG Bei Gewittern sollten Sie keine Arbeiten am Ger t vornehmen und keine Kabel an bzw abklemmen AVERTISSEMENT...

Page 86: ...m een wisselstroomeenheid gaat Voor gelijkstroomeenheden moet u de stroom bij de stroomonderbreker loskoppelen ADVARSEL F r du arbeider p et chassis eller arbeider i n rheten av str mforsyninger frako...

Page 87: ...nutenzione UPOZORNENIE Toto zariadenie m e ma viac ne jednu pr pojku nap jania Pred servisom treba v etky pripojenia odobra alebo odpoji od nap tia ADVERT NCIA Esta unidade pode ter mais de uma conex...

Page 88: ...tallieren Sie diese vor der Installation oder Wartung des Ger ts im Gestell AVERTISSEMENT Pour viter toute blessure corporelle pendant les op rations de montage d entretien ou de r paration de cette u...

Page 89: ...delle istruzioni del produttore del rack Durante il montaggio di questa unit in un rack con altri dispositivi iniziare a caricare il rack dal basso in alto con il componente pi pesante sul fondo del...

Page 90: ...N Stromversorgungen geeignet AVERTISSEMENT Ce dispositif a t con u pour fonctionner avec des syst mes d alimentation TN VARNING Enheten r avsedd att anv ndas med TN str msystem WAARSCHUWING Het appara...

Page 91: ...Wide Packets Customer Support using any of the following methods Address Ciena Corporation 1201 Winterson Road Linthicum MD 21090 Internet Site Additional contact information and general product supp...

Page 92: ...al support on the LightningEdge family of products contact the Ciena World Wide Packets Technical Support department by phone or fax North America 800 Ciena24 1 800 243 6224 or 1 410 865 4961 EMEA 800...

Page 93: ...l operating conditions Command File is a that contains a set of instructions on how to deliver the various system software to LightningEdge devices Condition refers to an occurrence within the system...

Page 94: ...ed on MAC addresses either by defining static MAC addresses or by limiting the number of dynamic MAC addresses that are allowed to access the port Severity the degree of urgency to which an event is g...

Reviews: