HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 18.752 B
Water chillers
Heat pump
HYDROCIAT LW
o
ptions
Options
Description
Advantages
LW ST/HE
Medium-temperature
brine solution
Implementation of new control algorithms and redesigned
evaporator to allow chilled brine solution production down
to -6°C when ethylene glycol is used (-3°C with propylene
glycol)
Covers specific applications such as ice storage and industrial
processes
Only sizes :
1328/1528/2628/3008
Low-temperature
brine solution
Implementation of new control algorithms and redesigned
evaporator to allow chilled brine solution production
down to -12°C when ethylene glycol is used (-8°C with
propylene glycol)
Covers specific applications such as ice storage and industrial
processes
Only HE sizes :
1328/1528
Light-brine solution,
down to -3°C
Implementation of new control algorithms and redesigned
evaporator to allow chilled brine solution production down
to -3°C when ethylene glycol is used (0°C with propylene
glycol)
Matches with most application requirements for ground-sourced
heat pumps and fits with many industrial processes requirements
●
Unit supplied in two
assembled parts
The unit is equipped with flanges that allow disassembly
of the unit on site
Facilitates installation in plant rooms with limited access
Only sizes:
4228/4408/4608/4628
Evap. single pump
power/control circuit
Unit equipped with an electrical power and control circuit
for one pump evaporator side
Quick and easy installation: the control of fixed speed pumps is
embedded in the unit control
708-3428
230V electrical plug 230V AC power supply source provided with plug socket
and transformer (180 VA, 0,8 Amps)
Permits connection of a laptop or an electrical device during unit
commissioning or servicing
●
Evaporator with one
pass less
Evaporator with one pass on the water side. Evaporator
inlet and outlet on opposite sides.
Easy to install, depending on site. Reduced pressure drops
●
Master/slave
operation
Unit equipped with supplementary water outlet
temperature sensor kit (to be field installed) allowing
master/slave operation of two units connected in parallel
Optimised operation of two units connected in parrallel operation
with operating time equalisation
●
Condenser with one
pass less
Condenser with one pass on the water side. Condenser
inlet and outlet on opposite sides.
Easy to install, depending on site. Reduced pressure drops
●
21 bar evaporator
Reinforced evaporator for extension of the maximum
water-side service pressure to 21 bar (standard 10 bar)
Covers applications with a high water column evaporator side
(typically high buildings)
●
Single power
connection point
Unit power connection via one main supply connection
Quick and easy installation
2800/4628
21 bar condenser
Reinforced condenser for extension of the maximum
water-side service pressure to 21 bar (standard 10 bar)
Covers applications with a high water column condenser side
(typically high buildings)
●
Reversed
evaporator water
connections
Evaporator with reversed water inlet/outlet
Easy installation on sites with specific requirements
●
Reversed condenser
water connections
Condenser with reversed water inlet/outlet
Easy installation on sites with specific requirements
●
Condenser
insulation
Thermal condenser insulation
Minimizes thermal dispersions condenser side (key option for
heat pump or heat recovery applications)
●
Service valve set
Liquid line valve (evaporator inlet) and compressor
suction line valve
Allow isolation of various refrigerant circuit components for
simplified service and maintenance
●
Lon gateway
Bi-directional communication board complying with Lon
Talk protocol
Connects the unit by communication bus to a building
management system
●
Control for low cond.
temperature
Output signal (0-10 V) to control the condenser water
inlet valve
Simple installation: for applications with cold water at condenser
inlet (ex. ground-source, groundwater-source, superficial
water-source applications) the signal permits to control a 2 or
3-way valve to maintain condenser water temperature (and so
condensing pressure) at acceptable values
●
Compliance with
Swiss regulations
Additional tests on the water heat exchangers: supply
(additional of PED documents) supplementary certificates
and test certifications
Conformance with Swiss regulations
●
● ALL MODELS
Refer to the selection tool to find out which options are not compatible