23
HYDROCIA
T L
W
HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 18.752 B
Water chillers
Heat pump
LW HE
1328
1528
1928
2128
2328
2628
3028
3428
3828
4228
4628
Power circuit
Nominal voltage
V-ph-Hz
400-3-50
Voltage range
V
360-440
Control circuit
24 V via the built-in transformer
Nominal start-up current
(1)
Circuit A
A
587
587
772
772
772
587
587
772
772
772
772
Circuit B
A
-
-
-
-
-
587
587
587
772
772
772
Single power connection point option
A
-
-
-
-
-
749
757
943
965
986
1004
Maximum start-up current
(2)
Circuit A
A
587
587
772
772
772
587
587
772
772
772
772
Circuit B
A
-
-
-
-
-
587
587
587
772
772
772
Single power connection point option
A
-
-
-
-
-
862
887
1072
1172
1202
1232
Cosine phi
Nominal
(3)
0.88
0.88
0.84
0.86
0.87
0.87
0.88
0.86
0.85
0.86
0.87
Maximum
(4)
0.91
0.92
0.90
0.90
0.90
0.91
0.92
0.91
0.91
0.91
0.91
Total harmonic distortion
(4)
%
0
0
0
0
0
0
0
0
0
0
0
Maximum power input*
Circuit A
kW
173
191
252
271
290
173
191
252
252
271
290
Circuit B
kW
-
-
-
-
-
173
191
191
252
271
290
Single power connection point option
kW
-
-
-
-
-
346
382
443
504
542
580
Nominal input current
(3)
Circuit A
A
162
171
210
230
250
162
171
210
210
230
250
Circuit B
A
-
-
-
-
-
162
171
171
210
230
250
Single power connection point option
A
-
-
-
-
-
324
342
381
420
460
500
Maximum input current (Un)*
Circuit A
A
275
300
400
430
460
275
300
400
400
430
460
Circuit B
A
-
-
-
-
-
275
300
300
400
430
460
Single power connection point option
A
-
-
-
-
-
550
600
700
800
860
920
Maximum input current (Un -10%)
(4)
Circuit A
A
300
330
419
455
476
300
330
419
419
455
476
Circuit B
A
-
-
-
-
-
300
330
330
419
455
476
Single power connection point option
A
-
-
-
-
-
600
660
749
838
910
952
(1) Instantaneous start-up current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced start-up current of the largest compressor).
Values obtained at standard Eurovent unit operating conditions: evaporator entering/leaving water temperature = 12°C/7°C, condenser entering/leaving water temperature
= 30°C/35°C.
(2) Instantaneous start-up current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced start-up current of the largest compressor).
Values obtained at operation with maximum unit power input.
(3) Values obtained at standard Eurovent unit operating conditions: evaporator entering/leaving water temperature = 12°C/7°C, condenser entering/leaving water temperature
= 30°C/35°C.
(4) Values obtained at operation with maximum unit power input.
*
Values obtained in operation with maximum unit power input. Values given on the unit name plate.
e
lectRical
Data
notes
h
igh
efficiency
Units
foR
high
conDensing
tempeRatURes
H
Summary of Contents for HYDROCIAT LW HE Series