WATER LEAK
42
Tr
ouble
Shooting
Check to see if Ambient tank is (25%)
full.
DC Current Check :
When there is water DC 0V;
No water DC 5V
Check the Cold Water Level Sensor.
12-5-A. COLD WATER LEVEL SENSOR DEFECT
Symptom
1. Ambient water is not full.
2. Water keeps flowing to drain.
3. Water is dripping down from Ice dispense tunnel / rotator blade.
Cause of Defect
1. Sensor will not work properly and will cause water to overflow.
2. Sensor will not work properly and will prevent water from filling.
AS Procedure
Change Cold Water Level Sensor, if necessary.
How to Diagnose
1
3
2
** Check black and brown wires.