12-3
AxLE COUPLING REPLACEMENT
36
Tr
ouble
Shooting
12-3-A. EVA ASSEMBLY DEFECT
Symptom
1. Cold water is working properly, but there is no Ice.
2. Connect Test Board: LED22 starts blinking.
Cause of Defect
EVA positioning is not level causing Ice to over freeze and/or freeze irregularly; thus causing axel
coupler to break or not function properly.
AS Procedure
Exchange Ice Full sensor(s).
How to Diagnose
Press the Ice button to dispense Ice.
2. There is Ice, but Ice shape is irregular.
- Remove Front-upper cover and disassemble the dispense tunnel to check the shape of Ice.
1
2
Two Ice frozen
together
Ice is lopsided
EVA positioning is not parallel,
causing Ice to over freeze and/
or freeze irregularly.