High Power Electronic Load 63200A Series Operation & Programming Manual
4-44
[ADVance:]EXTernal:WAVeform:CC:VRNG
Type:
Channel-Specific
Description:
Set the voltage measurement range in external waveform when the
mode is set to CC mode.
Setting Syntax:
[ADVance:]EXTernal:WAVeform:CC:VRNG<space><CRD | NR1>
Setting Parameters:<CRD | NR1>, LOW | L | 0, MIDDLE | M | 1, HIGH | H | 2
Setting Example: EXT:WAV:CC:VRNG HIGH
Set voltage range to High.
EXT:WAV:CC:VRNG M
Set voltage range to Middle.
EXT:WAV:CC:VRNG 0
Set voltage range to Low.
Query Syntax:
EXTernal:WAVeform:CC:VRNG?
Return Parameters:<CRD>, LOW(0), MIDDLE(1), HIGH(2)
[Unit = None]
Query Example:
EXT:WAV:CC:VRNG?
[ADVance:]EXTernal:WAVeform:CR:IRNG
Type:
Channel-Specific
Description:
Set the current measurement range in external waveform when the
mode is set to CR mode.
Setting Syntax:
[ADVance:]EXTernal:WAVeform:CR:IRNG<space><CRD | NR1>
Setting Parameters:<CRD | NR1>, LOW | L | 0, MIDDLE | M | 1, HIGH | H | 2
Setting Example: EXT:WAV:CR:IRNG HIGH
Set current range to High.
EXT:WAV:CR:IRNG M
Set current range to Middle.
EXT:WAV:CR:IRNG 0
Set current range to Low.
Query Syntax:
EXTernal:WAVeform:CR:IRNG?
Return Parameters:<CRD>, LOW(0), MIDDLE(1), HIGH(2)
[Unit = None]
Query Example:
EXT:WAV:CR:IRNG?
[ADVance:]External:WAVeform:CV:IRNG
Type:
Channel-Specific
Description:
Set the current measurement range in external waveform when the
mode is set to CV mode.
Setting Syntax:
[ADVance:]EXTernal:WAVeform:CV:IRNG<space><CRD | NR1>
Setting Parameters:<CRD | NR1>, LOW | L | 0, MIDDLE | M | 1, HIGH | H | 2
Setting Example: EXT:WAV:CV:IRNG HIGH
Set current range to High.
EXT:WAV:CV:IRNG M
Set current range to Middle.
EXT:WAV:CV:IRNG 0
Set current range to Low.
Query Syntax:
EXTernal:WAVeform:CV:IRNG?
Return Parameters:<CRD>, LOW(0), MIDDLE(1), HIGH(2)
[Unit = None]
Query Example:
EXT:WAV:CV:IRNG?
DIGITIZING Subsystem
4.3.2.9
DIGitizing:ABORt
Type:
Channel-Specific
Description:
Abort the digitizing function.
Setting Syntax :
DIGitizing:ABORt
Setting Parameters:None
Setting Example: DIG:ABOR
Abort digitizing function.
Query Syntax:
None
Return Parameters:None
Query Example:
None
Summary of Contents for 63200A Series
Page 1: ...High Power Electronic Load 63200A Series Operation Programming Manual ...
Page 2: ...High Power Electronic Load 63200A Series Operation Programming Manual Version 1 0 March 2015 ...
Page 7: ...vi ...
Page 11: ......
Page 15: ......
Page 22: ...Overview 1 7 Figure 1 3 Dimension of 63200A with Protection Cover ...
Page 23: ......
Page 31: ......
Page 127: ......