Remote Operation
4-27
BATT:VAL MIN
Set current = minimum value.
When BATT:MODE set to CR mode, then
BATT:VAL 0.5
Set resistance = 0.5
Ω.
BATT:VAL 500mΩ
Set resistance = 0.5Ω.
BATT:VAL MAX
Set resistance = maximum value.
BATT:VAL MIN
Set resistance = minimum value.
When BATT:MODE set to CP mode, then
BATT:VAL 0.5
Set power = 0.5W.
BATT:VAL 500mW
Set power = 0.5W.
BATT:VAL MAX
Set power = maximum value.
BATT:VAL MIN
Set power = minimum value.
Query Syntax:
[ADVance:]BATTery:VALue?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Ampere | Ohm | Watt]
Query Example:
BATT:VAL?
BATT:VAL? MAX
BATT:VAL? MIN
[ADVance:]BATTery:RISE
Type:
Channel-Specific
Description:
Set rising slew rate of current in battery discharge mode.
Setting Syntax:
[ADVance:]BATTery:RISE<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.
Setting Example: BATT:RISE 0.1
Set slew rate = 0.1A/μs
BATT:RISE 100mA/μs
Set slew rate = 0.1A/μs
BATT:RISE MAX
Set slew rate = maximum value.
BATT:RISE MIN
Set slew rate = minimum value.
Query Syntax:
[ADVance:]BATTery:RISE?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = A/uS]
Query Example:
BATT:RISE?
BATT:RISE? MAX
BATT:RISE? MIN
[ADVance:]BATTery:FALL
Type:
Channel-Specific
Description:
Set falling slew rate of current in battery discharge mode.
Setting Syntax:
[ADVance:]BATTery:FALL<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.
Setting Example: BATT:FALL 0.1
Set slew rate = 0.1A/μs
BATT:FALL 100mA/μs
Set slew rate = 0.1A/μs
BATT:FALL MAX
Set slew rate = maximum value.
BATT:FALL MIN
Set slew rate = minimum value.
Query Syntax:
[ADVance:]BATTery:FALL?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = A/uS]
Query Example:
BATT:FALL?
BATT:FALL? MAX
BATT:FALL? MIN
[ADVance:]BATTery:ENDVoltage
Type:
Channel-Specific
Description:
Set end voltage for battery discharge mode.
Setting Syntax:
[ADVance:]BATTery:ENDVoltage<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.
Summary of Contents for 63200A Series
Page 1: ...High Power Electronic Load 63200A Series Operation Programming Manual ...
Page 2: ...High Power Electronic Load 63200A Series Operation Programming Manual Version 1 0 March 2015 ...
Page 7: ...vi ...
Page 11: ......
Page 15: ......
Page 22: ...Overview 1 7 Figure 1 3 Dimension of 63200A with Protection Cover ...
Page 23: ......
Page 31: ......
Page 127: ......