High Power Electronic Load 63200A Series Operation & Programming Manual
4-6
Chapter
Standard Event Status Event Register
Bit Position
7
6
5
4
3
2
1
0
Condition
PON 0
CME EXE DDE QYE 0 OPC
Bit Weight
128 64
32
16
8
4
2
1
Query Syntax:
*ESR?
Return Parameters: <NR1>
Query Example:
*ESR? Return the Standard Event Status register readings.
Return Example: 48
*IDN? Identification Query
Type:
System Interface
Description:
This query requests the host to identify itself.
Query Syntax
*IDN?
Return Parameters:<aard>
Query Example:
*IDN?
String
Information
Chroma ATE Inc.
Manufacture
63205A-150-500
Model
63205A000001
Serial number
1.00
HOST‘s version of F/W
1.00
HOST‘s version of FPGA
1.00
HOST‘s version of PCB
Return Example:
Chroma ATE Inc.,63205A-150-500,63205A000001,1.00,1.00,1.00
*OPC Operation Complete Command
Type:
Device Status
Description:
This command causes the interface to set the OPC bit (bit 0) of the
Standard Event Status register when the Electronic Load has
completed all pending operations.
Setting Syntax:
*OPC
Setting Parameters: nil
*OPC? Operation Complete Query
Type:
Device Status
Description:
This query returns an ASCII “1” when all pending operations are
completed.
Query Syntax:
*OPC?
Return Parameters:<NR1>
Query Example:
1
*RCL Recall Instrument State Command
Type:
Device Status
Description:
This command restores the electronic load to a state that was
previously stored in memory with the *SAV command to the
specified location (see *SAV).
Setting Syntax:
*RCL<space><NR1>
Setting Parameters:<NR1>, 0 ~ 10, 0:Factory default file, 1~10:User define file
Setting Example: *RCL 5
Summary of Contents for 63200A Series
Page 1: ...High Power Electronic Load 63200A Series Operation Programming Manual ...
Page 2: ...High Power Electronic Load 63200A Series Operation Programming Manual Version 1 0 March 2015 ...
Page 7: ...vi ...
Page 11: ......
Page 15: ......
Page 22: ...Overview 1 7 Figure 1 3 Dimension of 63200A with Protection Cover ...
Page 23: ......
Page 31: ......
Page 127: ......