High Power Electronic Load 63200A Series Operation & Programming Manual
4-12
Query Example:
CONF:SYNC:MODE?
CONFigure:PARAllel:INITial
Type:
All Channel
Description:
Set Load into/exit parallel mode.
Setting Syntax:
CONFigure:PARAllel:INITial<space><CRD | NR1>
Setting Parameters: <CRD | NR1>, OFF(0), ON(1)
Setting Example: CONF:PARA:INIT ON
Set Load to into parallel mode.
CONF:PARA:INIT 0
Set Load to exit parallel mode.
Query Syntax:
CONFigure:PARAllel:INITial?
Return Parameters:<CRD>, OFF(0), ON(1)
[Unit = None]
Query Example:
CONF:PARA:INIT?
CONFigure:PARAllel:MODE
Type:
Channel-Specific
Description:
Set the parallel mode.
Setting Syntax:
CONFigure:PARAllel:MODE<space><CRD | NR1>
Setting Parameters: <CRD | NR1>, NONE(0), MASTER(1), SLAVE(2)
Setting Example: CONF:PARA:MODE MASTER
Set parallel mode to MASTER.
CONF:PARA:MODE 0
Set parallel mode to NONE.
Query Syntax:
CONFigure:PARAllel:MODE?
Return Parameters:<CRD>, NONE(0), MASTER(1), SLAVE(2) [Unit = None]
Query Example:
CONF:PARA:MODE?
CONFigure:AUTO:ON
Type:
Channel-Specific
Description:
Set the load module to perform auto load on during power-on.
Setting Syntax:
CONFigure:AUTO:ON<space><CRD | NR1>
Setting Parameters:<CRD | NR1>, OFF(0), ON(1)
Setting Example: CONF:AUTO:ON ON
Set auto load on state to ON.
CONF:AUTO:ON 0
Set auto load on state to OFF.
Query Syntax:
CONFigure:AUTO:ON?
Return Parameters:<CRD>, OFF(0), ON(1) [Unit = None]
Query Example:
CONF:AUTO:ON?
CONFigure:ENTer:KEY
Type:
Channel-Specific
Description:
Set the action type of ENTER key.
Setting Syntax:
CONFigure:ENTer:KEY<space><CRD | NR1>
Setting Parameters: <CRD | NR1>, NEXT(0), FIXED(1)
Setting Example: CONF:ENT:KEY NEXT
Set ENTER key function to NEXT.
CONF:ENT:KEY 1
Set ENTER key function to FIXED.
Query Syntax:
CONFigure:ENTer:KEY?
Return Parameters: <CRD>, NEXT(0), FIXED(1)
[Unit = None]
Query Example:
CONF:ENT:KEY?
CONFigure:SHORt:KEY
Type:
Channel-Specific
Description:
Set the action enable or disable of SHORT key.
Setting Syntax:
CONFigure:SHORt:KEY<space><CRD | NR1>
Setting Parameters: <CRD | NR1>, HOLD(0), TOGGLE(1) , DISABLE(2)
Setting Example: CONF:SHOR:KEY DISABLE
Set SHORT key function to
disable.
Summary of Contents for 63200A Series
Page 1: ...High Power Electronic Load 63200A Series Operation Programming Manual ...
Page 2: ...High Power Electronic Load 63200A Series Operation Programming Manual Version 1 0 March 2015 ...
Page 7: ...vi ...
Page 11: ......
Page 15: ......
Page 22: ...Overview 1 7 Figure 1 3 Dimension of 63200A with Protection Cover ...
Page 23: ......
Page 31: ......
Page 127: ......