4. Tighten the screw to secure the harness in place.
Ensure the wire insulation is not crimped under the screw.
5. Slide the selector switch to the 200V location.
6. Re-attach the front panel.
Configuring ballast settings for 400 VAC operation
Convert the voltage to 400 VAC for the lamp power supply (LPS).
1. Unplug the LPS from power.
2. Remove the front panel using a Philips screwdriver.
3. Insert the convenience outlet harness (black) wire into the second position on the terminal
block.
Installation and Setup
Roadie 4K35 Quick Start Guide
20
020-101671-04 Rev. 1 (01-2016)
Copyright
©
2016 Christie Digital Systems USA Inc. All rights reserved.