Danger! Failure to comply with the following results in death or serious injury.
•
FIRE HAZARD! Do not cross-connect the high current DC cables of the lamp power
supply and the projector's interlock/control cables in a multi-projector installation.
8. Set the three LPS breakers to their on positions.
9. Set the projector breaker, located on the baseplate below the projector AC receptacle, to the
on position.
Configuring ballast settings for 200 VAC operation
Convert the voltage to 200 VAC for the lamp power supply (LPS).
1. Unplug the LPS from power.
2. Remove the front panel using a Phillips screwdriver.
3. Insert the convenience outlet harness (black) wire into the first position on the terminal
block.
Installation and Setup
Roadie 4K35 Quick Start Guide
19
020-101671-04 Rev. 1 (01-2016)
Copyright
©
2016 Christie Digital Systems USA Inc. All rights reserved.