Manage Automation
Christie Integrated Media Block User Manual
51
020-100845-05 Rev. 1 (08-2013)
10. Repeat steps 2 to 9 and add these activities:
Add Christie ACT Automation to a Macro
You can use a GPIO control or an external automation device such as a Christie ACT to control
automated events in your theatre. To add Christie ACT automations to a macro, you must add the
Christie ACT to the Device Type list and define its connection parameters including the IP address,
log in user name, and password.
In this example, the Christie ACT uses these scripts to control lighting:
• Lights-0 - lights at 0%
• Lights-50 – lights at 50%
• Lights-100 – lights at 100%
Automation Type
Field Settings
Lights 50% (GPO 4 High, GPO 5 High)
Automation Device: IMB Automation
Activity Type: GPO Set
PIN Number: 5
Signal Direction: Low
Douser Close
Automation Device: Projector
Activity Type: Projector
Action: Douser Close
Lamp Off
Automation Device: Projector
Activity Type: Projector
Action: Lamp Off