Section 4: OPERATION
GS Series User Manual
020-000724-02 Rev. 1 (10-2015)
4-13
• Manual
Adjustment
1
Adjust color slide bars and judge image color by eye or meter. A user-
defined color "adjustment" can be applied.
2
Use this submenu if you do not have specific color coordinates in mind
and will judge color performance by eye or meter. As for Meter
Adjustment, each color control actually defines new x/y coordinates for
that color and changes its hue. The main colors (red part of red, green
part of green and blue part of blue) adjust the intensity of that color
component, while the modifying colors (e.g. green part of red and blue
part of red) modify the x and y value and change the hue of that color.
At the same time the main colors also are used to control the color of
the white point.
Hot-Key Settings
Assign a different function to the hot-key on the remote control by highlighting
the function in the list and pressing ENTER. Choose a function that does not
already have a dedicated button, and assign the hot-key to that function,
allowing you to quickly and easily use the chosen function.
Service
•
Projector Info: Display current projector settings (read-only).
•
Factory Reset: Restore all settings to their default value. It will not reset
network but it will reset RS232.
•
Test Pattern: Choose the desired internal test pattern to display, or select
OFF to turn off a test pattern.
•
Phosphor Index: The Phosphor index synchronizes the phosphor wheel
with the filter wheel and DMD. The index defines the delay between the
wheel and the DMD. When the Phosphor index is adjusted, it will impact
the smoothness and contouring of the R/G/B gray level.
•
Filter Index: The Filter index synchronizes the filter wheel with the phosphor
wheel and DMD. The index defines the delay between the wheel and the
DMD. When the filter index is adjusted, it will impact the smoothness of the
white color space without contouring, similar to the phosphor index
behavior.
•
Error log: Show the projector error log for debug.
•
Mode Adjustment: Fine tune the H and V start position for a signal in the
EDID timing table and record the values in the system to override the timing
table. The settings must be "Saved to Record" before exiting the menu, or
they will be lost. To revert to original timing table settings, each setting must
be manually cleared. Factory Defaults will not clear these override settings.
•
Laser Diode Info: Display current laser banks status and temperature
information.
•
High temperature warning: Show the warning message the when the
ambient temperature is over 35°C.