ROTA
Set to 1 acknowledge the Lamp Rotation Warning. Will auto clear at lamp life or on lamp change.
ROTW
0 - No warning will be generated.
1 - Lamp Rotation Warning will be generated when lamp hours extends past 1/2 lamp life. Warning will be
reported in SST. Warning will be cleared by LPL+ROTA or changing the lamp.
EXAMPLES:
(LPL 1500) Set lamp life limit to 500 hours.
(LPL 0) Set lamp life limit to default hours based on the lamp type.
(LPL ?) Get lamp life limit.
(LPL+LIFE 1) Enable lamp expired message.
(LPL+LIFE 0) Disable lamp expired message.
(LPL+ROTW 1) Enable lamp rotation message.
(LPL+ROTA 1) Acknowledge that lamp was rotated.
LAMP MODE (LPM)
Set lamp mode to constant power or LiteLOC™ for global and per channel. NOTE: This command can only be
used to update the current lamp file. Changing the lamp power for the current channel will change the lamp power
for any channel using the same lamp file.
SUBCODE
DESCRIPTION OF USE
Cxxx
Replace Cxxx with the channel number. Valid range is 101-164.
NONE
Set lamp mode for the current channel.
EXAMPLES:
(LPM 0) Set Constant Power mode for current channel
(LPM “Constant Power”) Set Constant Power mode for active channel
(LPB+C101 1) Set intensity mode for channel 1
(LPM?) Get Lamp mode for active channel
LAMP POWER (LPP)
Set lamp power to be used when in Constant Power mode. NOTE: This command can only be used to update the
current lamp file. Changing the lamp power for the current channel will change the lamp power for any channel
using the same lamp file.
SUBCODE
DESCRIPTION OF USE
Cxxx
Replace Cxxx with the channel number. Valid range is 101-164.
MINI
Get nominal minimum lamp power for the current lamp. Read-only value
NONE
Set lamp power for the current channel.
EXAMPLES:
(LPP 2500) Set lamp power to 2500 for current channel
(LPP+C102 2000) Set lamp power to 2000 for channel 2
(LPP+C102?) Get the lamp power for channel 2