7-4
D4K25 Service Manual
020-100880-01 Rev. 1 (06-2012)
Section 7: Serial API
ENABLE ERROR MESSAGES (EME)
Enable broadcasting error messages.
SUBCODE
DESCRIPTION OF USE
FANF
0 - No Fan Fail warning will be generated,
1 - Fan Fail warning will be generated.
NONE
0 - Disable broadcast,
1 - Enable broadcast of error messages to all connected serial ports and telenet sessions.
TEMP
0 - No Over Temperature warning will be generated,
1 - Over Temperature warning will be generated.
EXAMPLES:
(EME 1) Enable broadcasting error messages
(EME+FANF 0) Disable fan fail alarm warnings
(EME?) Requests current state of broadcast. Example response is (EME!001)
FOCUS LENS POSITION ADJUSTMENT (FCS)
Adjust lens to specific focus position with a specified direction. NOTE: This command can only be used to update
the current ILS file. Changing the focus for the current channel will change the focus for any channel using the
same ILS file.
Use command without subcode:
• If ILS is ON, motor will move to specified steps, and save data to the active channel.
• If ILS is OFF, motor will move to specified steps. Do not save data to the active channel.
SUBCODE
DESCRIPTION OF USE
BACN
Motor backlash in negative direction. Read-only.
BACP
Motor backlash in positive direction. Read-only.
CALB
Calibrate travel range and backlash on specified. Only valid parameter for this command is 1.
SET only command.
Cxxx
Replace Cxxx with the channel number. Valid range is 101-164.
NONE
Moving lens mount to a specified vertical position with a specified direction.
RNGN
Motor moving range in negative direction
. Read-only.
RNGP
Motor moving range in positive direction. Read-only.
RSET
Move motor to the center flag then move back to current position.
Only valid parameter for this com-
mand is 1.
SET only command.
STRT