7-22
D4K25 Service Manual
020-100880-01 Rev. 1 (06-2012)
Section 7: Serial API
Cxxx
Replace xxx with the channel number. Valid range is 101 - 164.
NONE
Select source format for the current channel.
EXAMPLES:
(SRF+C108 “XXX”) Use file “XXX” on channel 108
(SRF+C108?) Get source file name on channel 108
(SRF?L) List all entries of source control
(SRF+RFSH 1) Refresh TI file list
SYSTEM STATUS (SST)
R
etrieve the various system status groups.
SUBCODE
DESCRIPTION OF USE
ALRM
Returns a summary of any active alarms
CONF
Returns configuration data - model, sn, build date, etc
COOL
Returns cooling data - cooling fans, air flow, etc
HLTH
Returns system health
INTE
Returns interlock data
LAMP
Returns lamp operational data.
NONE
Returns information on all status groups, with one message per item.
PERI
Returns peripherals data - Cine-IPM, etc
SECU
Returns security data
SERI
Return serial numbers
SIGN
Returns signal data - freq, etc.
SYST
Returns system data - power, hours of use, shutter open, etc
TEMP
Returns temperature data
VERS
Returns version numbers
EXAMPLE:
(SST+ALRM?) returns (SST+ALRM!000 002 “101” “Prism temperature”) where parameters are:
P1=index number,
P2=error level,
P3=value,
P4=description.
Error level is:
0=no errors or warnings,
1=warning,
2=error,
3=error and warning