background image

Integrated Motorized Screen

User Manual for SkyShow 

Series Model D

Suitable for Model Named SK-MI(F)

Protecting your Screen:

To  ensure  long  lasting  viewing  enjoyment  keep 
the  screen  rolled  up  when  not  in  use.  Check  both 
the front and back surfaces before retracting into 
the case to make sure it is free of dust, dirt, insects 
or other foreign matter. Use a soft brush or cloth to 
lightly remove any foreign particles.

Cleaning your Screen:

Use  warm  water  with  a  mild  detergent  to  remove 
any  marks  on  the  surface  or  screen  casing  (only 
dab, do not rub). Immediately dry the screen with 
a soft cloth or towel. Do not leave it to air dry.

Never use any solvents, chemicals or abrasive 
cleaners on the screen surface as they can 
permanently damage the screen surface.

Screen:  Voltage AC220-230V/50-60HZ, 0.8Amp, power 190watts.
RF remote(F):  Voltage 3V, use CR2450*1 battery.
Radio Frequency:  433Hz. maximum control distance 15m.

Setting for Up and Down Limited Positioning for Motor:

The limited positioning of motor has been defaulted when 
EX-factory, it is not allowed to reset. 

Note:

When setting RS232 or RS485, if the screen is not able to 
operate as it is, please switch position of No. 1 and No. 2.
The electric resistance of return circuit is less than 20

Ω

.

Do not do wiring nearby interference sources. 

RS485/RS232 control protocal:
     Baud Rate: 2400
      Data Bits: 8
      Stop Bits: 1
      Parity: None
Hex command:
     Screen UP: ff ee ee ee dd
     Stop: ff ee ee ee cc
     Down: ff ee ee ee ee
     In some cases you may need to 
     enable the RS-232 control by 
     sending hex command: 
     ff ee ee ee aa

P1

DB9

1
6
2
7
3

5

TXD

GND

6
5
4
3
2
1

6P6C

8
4
9

D.  RS485 or RS232 :
      From left to right, 1 & 2 cable for control. 
      For RS485, cable 1 is D-, cable 2 is D+. The 
      connecting of RS232 as figure shows.

USB Serial Port (COM3) Property

Detail Event

Drive Program

General Port 

Confirm

Advanced

Restore 

Baud Rate:

2400

Data Bits:

8

Parity:

None

Stop Bits:

1

Flow Control:

None

Cancel

RJ12

6P6C

6
5
4
3
2
1

UP

S1

S2

S3

DOWN

STOP

COM

RJ12

6P6C

6
5
4
3
2
1

UP

S1

DOWN

STOP

COM

S2

S3

123456

EXTERNAL 

CTRL

C.  LVC:
      Simply contact 
      RJ12 6P6C connector. 
      From left to right, 3-6 
      is control signal cable, 
      3 is common cable, 
      4 is stop, 5 is lower, 
      6 is lift.

   Trigger control

Use a small pin fit to size to insert into positioning setting 
keyhole at rear side of remote and press it to make the light on. 
Then press “down” key on remote to operate screen to go 
down. When screen moves to the required position, then press 
“stop” button. And please press positioning setting keyhole  
with pin again. This is the down positioning set as required. 
Please follow the same to set up limit,  Please check below:

Note:

  Maximum travel distance of steel wire is 5meters.

Reviews: