Integrated Motorized Screen
User Manual for SkyShow
Series Model D
Suitable for Model Named SK-MI(F)
Protecting your Screen:
To ensure long lasting viewing enjoyment keep
the screen rolled up when not in use. Check both
the front and back surfaces before retracting into
the case to make sure it is free of dust, dirt, insects
or other foreign matter. Use a soft brush or cloth to
lightly remove any foreign particles.
Cleaning your Screen:
Use warm water with a mild detergent to remove
any marks on the surface or screen casing (only
dab, do not rub). Immediately dry the screen with
a soft cloth or towel. Do not leave it to air dry.
Never use any solvents, chemicals or abrasive
cleaners on the screen surface as they can
permanently damage the screen surface.
Screen: Voltage AC220-230V/50-60HZ, 0.8Amp, power 190watts.
RF remote(F): Voltage 3V, use CR2450*1 battery.
Radio Frequency: 433Hz. maximum control distance 15m.
Setting for Up and Down Limited Positioning for Motor:
The limited positioning of motor has been defaulted when
EX-factory, it is not allowed to reset.
Note:
When setting RS232 or RS485, if the screen is not able to
operate as it is, please switch position of No. 1 and No. 2.
The electric resistance of return circuit is less than 20
Ω
.
Do not do wiring nearby interference sources.
RS485/RS232 control protocal:
Baud Rate: 2400
Data Bits: 8
Stop Bits: 1
Parity: None
Hex command:
Screen UP: ff ee ee ee dd
Stop: ff ee ee ee cc
Down: ff ee ee ee ee
In some cases you may need to
enable the RS-232 control by
sending hex command:
ff ee ee ee aa
P1
DB9
1
6
2
7
3
5
TXD
GND
6
5
4
3
2
1
6P6C
8
4
9
D. RS485 or RS232 :
From left to right, 1 & 2 cable for control.
For RS485, cable 1 is D-, cable 2 is D+. The
connecting of RS232 as figure shows.
USB Serial Port (COM3) Property
Detail Event
Drive Program
General Port
Confirm
Advanced
Restore
Baud Rate:
2400
Data Bits:
8
Parity:
None
Stop Bits:
1
Flow Control:
None
Cancel
RJ12
6P6C
6
5
4
3
2
1
UP
S1
S2
S3
DOWN
STOP
COM
RJ12
6P6C
6
5
4
3
2
1
UP
S1
DOWN
STOP
COM
S2
S3
123456
EXTERNAL
CTRL
C. LVC:
Simply contact
RJ12 6P6C connector.
From left to right, 3-6
is control signal cable,
3 is common cable,
4 is stop, 5 is lower,
6 is lift.
Trigger control
Use a small pin fit to size to insert into positioning setting
keyhole at rear side of remote and press it to make the light on.
Then press “down” key on remote to operate screen to go
down. When screen moves to the required position, then press
“stop” button. And please press positioning setting keyhole
with pin again. This is the down positioning set as required.
Please follow the same to set up limit, Please check below:
Note:
Maximum travel distance of steel wire is 5meters.