Page 1: ...Absenicon3 0 Series C165 User Manual ...

Page 2: ...cation 10 1 3 Screen Dimension Figure mm 11 1 4 Standard packaging 12 2 Product Installation 13 2 1 Installation guide 13 2 2 Installation method of wall mounted 14 2 2 1 Assemble frame 14 2 2 2 Install frame fixed connecting plate 15 2 2 3 Fixed the frame 16 2 2 4 Install cabinet 16 2 2 5 Install edging 17 2 2 6 Install module 19 ...

Page 3: ...e any questions please seek help from Absen Beware of Electric Shock To prevent electric shock the device must be properly grounded during installation Do not ignore using the grounding plug or else there is a risk of electric shock During a lightning storm please disconnect the device s power supply or provide other suitable lightning protection If the equipment is not in use for a long time plea...

Page 4: ...ion around the display screen controller power supply and other devices and keep a minimum 0 1 meter gap with other objects Do not stick or hang anything on the screen Do not modify the product do not add or remove parts Do not use the product in case ambient temperature is over 55 Beware of Injury Warning Wear a helmet to avoid injury Ensure any structures used to support fix and connect the equi...

Page 5: ... Please contact us directly for detailed environmental performance information WARNING Beware of suspended loads LED lamps used in the module are sensitive and can be damaged by ESD electrostatic discharge To prevent damage to LED lamps do not touch when the device is running or switched off WARNING The manufacturer shall not bear any responsibility for any incorrect inappropriate irresponsible or...

Page 6: ...CC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential are...

Page 7: ...e efficiency Absenicon3 0 series conference screens bring a brand new large screen visual experience for the conference room which can share the speaker s intelligent terminal content to the conference screen at any time without complicated cable connection and easily realize wireless projection of multi platform terminals of Windows Mac OS iOS and Android At the same time according to different c...

Page 8: ...ue light mode for eye protection bring comfortable experience 5 Ultra high contrast ratio of 5000 1 110 NTSC large color space showing colorful colors and the smallest visible details are in front of you 6 160 ultra wide display viewing angle everyone is the protagonist 7 28 5mm ultra thin thickness 5mm ultra narrow frame 8 Built in audio dividable frequency processing treble and bass ultra wide a...

Page 9: ...ates quickly and efficiently improve the welcome atmosphere 15 Support remote control can adjust brightness switch signal source adjust color temperature and other operations one hand can control various functions 16 All kinds of interfaces are available and peripheral devices can access 17 A variety of installation methods to meet your installation needs 2 people 2 hours rapid installation All mo...

Page 10: ...r consumption w 1800 System Parameters Android system Android8 0 System configuration 1 7G 64 bit quad core processor Mail T820 GPU System memory DDR4 4GB Storage capacity 16GB eMMC5 1 control interface MiniUSB 1 RJ45 1 I O interface HDMI2 0 IN 3 USB2 0 1 USB3 0 3 Audio OUT 1 SPDIF OUT 1 RJ45 1 Automatic sharing of network and control OPS Optional Support Environmental Parameters Operating Tempera...

Page 11: ...Absenicon3 0 C165 User Manual 11 1 3 Screen Dimension Figure mm Front view Rear view ...

Page 12: ...stallation structure packaging movable bracket or wall hanging edging The cabinet packaging is unified to 2010 870 500mm Three 1 4 cabinets free packaging into honeycomb box overall size 2010 870 500mm one 1 4 cabinet and four 4 1 4 module packages and edge into the honeycomb box dimensions 2010 870 500mm Installation structure packaging figure take the movable bracket as an example ...

Page 13: ...stall it according to the identification sequence number of our company Diagram of installation number front view Number description The first digit is the screen number the second digit is the cabinet number from top to bottom the top is the first row The third place is the cabinet column number For example 1 1 2 is the first row and the second column at the top of the first screen For example 3 ...

Page 14: ...ss beam and vertical beam Place it on the ground with the front facing upwards the side with the silk printed logo on the beam is the front Assemble the four sides of the frame including two beams two vertical beams and 8 M8 screws 横梁 The side of the beam with screw holes is facing up vertical beam The vertical beam has a gap on the side facing inward ...

Page 15: ...ng the installation position of the connecting plate on the back frame and the position of the screen body drill holes on the wall to install the fixed connecting plate only 4 connecting plates on the four sides can be installed when the wall bearing capacity is good Frame fixed connecting plate Each is fixed with 3 M8 expansion screws ...

Page 16: ...binet first and hook connecting plate on the back of the cabinet into the notch of the cross beam of the frame Move the cabinet to the center and align the marking line on the beam 2 The top two rows of cabinets are connected to the beams without hooks and are only connected by the left and right bolts between the cabinets Flat connecting plate Hook connecting plate Hook connecting plate Three mor...

Page 17: ...rner hook connecting plate of the screen are flat connecting plate Note The internal structure is subject to the actual product 2 2 5 Install edging 1 Install the edging under the screen and tighten the fixing screws of the left and right connecting plates of the bottom edging 16 M3 flat head screws Left and right connecting bolts left and right connecting plates of edging M4 Screw Cabinet Hook co...

Page 18: ...to the bottom row of cabinets tighten 6 M6 screws and connect the power and signal wires of the lower edging and the bottom cabinet Note The internal structure is subject to the actual product 3 Install the left right and top edging using M3 flat head screws ...

Page 19: ...19 Note The internal structure is subject to the actual product 2 2 6 Install module Install the modules in order of number Please refer to Absenicon3 0 C138 user manual for system operation instructions and maintenance instructions ...