Maintaining the projector
CP2306-RGBe, CP2308-RGBe, CP2310-RGBe User Manual
89
020-001835-02 Rev. 1 (05-2021)
Copyright
©
2021 Christie Digital Systems USA, Inc. All rights reserved.
Caution! If not avoided, the following could result in minor or moderate injury.
•
Do not operate the product without the filter installed.
•
Do not reuse an old air filter.
1.
Loosen the two captive screws on the bottom of the filter cover.
2.
Pull the cover out and down.
3.
Slide the air filter out and inspect it.
If the filter appears dirty and you cannot see through it, clean it (on page 90) if it is a washable
filter.
If the filter appears clean, continue to step 4.
4.
Replace the air filter with the airflow indicator facing toward the projector.
5.
Install the air filter cover by inserting the two bottom tabs and then pushing the cover closed.
6.
Tighten the two captive screws.
The filter is located on the right side of the projector behind the service access panel.
1.
Remove the top lid.
2.
Reach into the projector and then loosen the first service panel screw.
3.
Open the integrator rod access door and loosen the second service panel screw.
4.
Push the clips on the top of the service panel down and out to remove the service panel.
5.
Loosen the two captive screws on the cap plate and then remove it.
Summary of Contents for CP2306-RGBe
Page 1: ...CP2306 RGBe CP2308 RGBe CP2310 RGBe User Manual 020 001835 02...
Page 98: ......
Page 99: ......