Managing color setting files
CP2306-RGBe, CP2308-RGBe, CP2310-RGBe User Manual
46
020-001835-02 Rev. 1 (05-2021)
Copyright
©
2021 Christie Digital Systems USA, Inc. All rights reserved.
4.
Type a name for the MCGD file and tap Save.
Delete a Measured Color Gamut Data (MCGD) file when it is no longer required.
1.
In the left navigation menu, tap Color Settings > MCGD File Setup.
2.
In the MCGD File list, select a MCGD file.
3.
Tap Delete.
4.
To confirm the deletion, tap Delete.
Typically, Target Color Gamut Data (TCGD) file settings are defined by the content provider and are not
modified. A colorimeter is required to complete this procedure.
1.
Turn on the light source and allow it to operate for 20 minutes.
2.
In the left navigation menu, tap Color Settings > TCGD File Setup.
3.
Tap Create TCGD File.
4.
Type a name for the TCGD file and tap Create.
5.
To display test clips automatically when you select a color in the chromaticity image, select
6.
Automatically Display Test Clips.
7.
To modify the white clipping values and improve image detail in very bright areas of the image, select
Use White Clip.
8.
Tap the option button in the red area of the chromaticity image to display the red test pattern.
9.
Measure the red chromaticity with the colorimeter.
10.
Type the red chromaticity values in the Red X and Red Y fields.
11.
Adjust the Gain value to modify the color brightness.
12.
Repeat steps 8 to 10 for the magenta, blue, cyan, white, yellow, and green chromaticity
measurements.
13.
To adjust the color of the white light in a specific area of the screen, select White Tolerance and a
screen area.
14.
Tap Save.
Edit an existing Target Color Gamut Data (TCGD) file when color readings change.
1.
In the left navigation menu, tap Color Settings > TCGD File Setup.
2.
In the TCGD File list, select a TCGD file.
3.
Edit the TCGD file settings.