Ventilation and cooling
Vents and louvers provide ventilation, both for intake and exhaust, keeping the projector components
within their operating temperature specifications.
Do not install the projector near a radiator, heat register, or within an enclosure. To ensure adequate
airflow, follow the requirements specified in the line drawing (P/N: 020-000782-XX) and never block or
cover the vents.
When replacing fans, ensure you confirm the fan direction for airflow. The correct orientation of the
fan also ensures that the fan harness reaches the connector.
Replacing the lamp blower fans (#1, 2, 3)
Each lamp cartridge has six fans cooling the lamp modules. The blower fans #1, 2, and 3 cool the B1,
B2, and B3 lamps.
Estimated replacement time: 3.5 minutes for servicing a single lamp B blower fan
1. Remove the top cover (on page 34).
2. Loosen the two screws on the rear top support bracket and remove the bracket.
3. Remove the screw securing the lamp blower bracket.
4. Slide the bracket to clear the teeth securing the bracket.
Boxer 4K Service Guide
42
020-101699-04 Rev. 1 (02-2018)
Copyright
©
2018 Christie Digital Systems USA, Inc. All rights reserved.
Summary of Contents for Boxer 30
Page 1: ...Service Guide 020 101699 04 Boxer 4K...
Page 113: ......