2. Open the Service door on the side of the projector.
3. Unlock the Zoom and Focus paddles.
4. Adjust the magnification using the Zoom paddle.
Make sure you do not see any corners.
5. Adjust the focus using the Focus paddle.
Always focus the center of the image first and then make sure no blurry edges exist.
6. When complete, lock the Zoom and Focus paddles.
Adjusting DMD convergence
A convergence problem occurs when one or more projected colors (red, green, and blue) appears
misaligned when examined with a convergence test pattern.
The three colors should overlap to form pure white lines throughout the image and one or more poorly
converged individual colors may appear adjacent to some or all of the lines.
When adjusting the convergence, you are adjusting red and green to blue.
1. From the Test Pattern menu, select the Convergence test pattern.
Service setups
Boxer 4K Service Guide
22
020-101699-04 Rev. 1 (02-2018)
Copyright
©
2018 Christie Digital Systems USA, Inc. All rights reserved.