1.3 SPECIFICATIONS, CERTIFICATIONS, AND SIZING GUIDELINES
Sodium hypochlorite production:
NEXGEN60 - Up to 72 pounds per day at 7000ppm
NEXGEN60R – Up to 72 pounds per day at 7000ppm
Maximum pool return line pressure:
25 PSI including plumbing to and from the venturi injector
Electrical requirements:
NEXGEN60 and 60R
Rated 240 VAC, 87.12 A, 60 Hz.
Requires:
A 240 volt single phase connection @ 100 amps minimum and 60Hz
120 volt connection to a chemical feed controller or 120 volt outlet @1 amp
Internal System Fusing
Power Supply NEXGEN60 and 60R – 2 x 60 amp RK5 class fuse
Circulation Pump – 10 amp internal circuit breaker
Chemical Metering / Control – 12 amp internal circuit breaker
Certifications
NEXGEN60 and NEXGEN60R are certified for indoor installation.
NSF Standard 50
UL Standard 1081
CSA Standard C22.2 #218.1
PRMA Reg. No. 33004
Sizing guidelines
Chlorinator sizing must comply with local codes. Please contact your local health
department for specific requirements or contact your local ChlorKing representative for
assistance.