2.6 POWER SUPPLY ELECTRICAL CONNECTIONS
WARNING
BE SURE TO CONNECT THE EARTH TERMINALS AND THE EQUIPMENT BONDING
WIRE. THE ELECTRICAL SUPPLY MUST MATCH THE SYSTEM RATED CURRENT.
ENSURE THAT POWER IS LINKED TO THE MAIN PUMP POWER SOURCE FOR THE
POOL TO ENSURE THAT YOUR
CHLORKING®
NEXGEN SYSTEM NEVER
OPERATES WHEN THE POOL PUMPS ARE OFF.
For ease of service, it is recommended that a manual disconnect be installed
between the electrical service and the NEXGEN system.
Connect the electrical supply from the pool equipment room to the connections marked
240 VAC L1, L2 and ground. Ensure that the electrical service is protected by a circuit
interrupter and is rated for the model NEXGEN that is installed.
240 VAC
L1 and L2
Ground
240 VAC
L1 and L2