NEXGEN60 InstallationRev1
Page
14
of
42
04/11/2022
Plumb the inlet of the venturi to the booster pump which is connected to the return line of
the pool after all other pool components such as heaters etc. Use at least 2 inch PVC
pipe for this connection. It is recommended that a valve be installed at this connection
so that the system can be isolated from the pool.
Plumb the outlet of the venturi to the return line of the pool 18
inches after the inlet plumbing connection. Use at least 2 inch
PVC pipe for this connection. It is recommended that a valve
be installed at this connection so that the system can be
isolated from the pool.
Size Booster Pump based on return line
pressure
Return Line Pressure Pump Horsepower
5 PS!
½ HP
7 PSI
1 HP
12 PSI
2 HP
25 PSI
3 HP
PLUMBING THE PRESSURE SWITCH
Connect the pressure switch to the return line with ¼ tubing (not supplied) and the ¼
inch valve supplied. The pressure connection should provide a minimum of 5 psi when
the pool pump is on, and pressure should be less than 3 psi when the pool pumps are
off. Contact ChlorKing for installations that do not meet these specifications.
Inlet
Outlet
Pressure
Switch
Connection