39
Lighting
Open the door place a firelighter at the back of the furnace put 6-8 pieces of
kindling on top of the firelighter. Place 2 split logs on top of the kindling, set
the Air Flow Bar to setting III fully extended. Light the firelighter. If
condensation appears on the glass when the door is closed leave ajar and it
should clear in a minute or two. Do not leave stove unattended when door is
open.
The side and back bricks will go black, when they go clear about 12-20
minutes the fire can be turned down using the Air Flow Bar to the desired
setting (normally between setting I and II ). The quality of your fuel and
chimney draft will dictate your setting.
Refuelling on to a low fire bed
If there is insufficient burning material in the fire bed to ignite fresh fuel,
excessive smoke emission can occur. Refuelling must be carried out on a
sufficient quantity of glowing embers and ash so that the fresh fuel charge will
ignite in a reasonable period. If there are too few embers in the fire bed, add
suitable kindling to prevent excessive smoke
Fuel overloading
The maximum amount of fuel specified in this manual should not be
exceeded, overloading can cause excess smoke.
Operation with door left open
Operation with the door open can cause excess smoke. The appliance must
not be operated with the appliance door left open except as directed in the
instructions.
Refuelling
Always refuel on a hot bed of ash.
Pull Air Flow Bar fully out to setting III. Slowly open the door with the glove
provided equalising the pressure inside the fire cube with the room (if you
open the door quickly ash will be lifted from the furnace into the room). Place
2-3 logs bark side down onto a bed of hot ashes and close the door. When the
logs have fully turned black set Air Flow Bar to desired setting.
Solid Fuel
The grate should be cleaned out before every lighting using the riddle lever.
Set fuel selector to solid fuel (forward position).
Open door, place 2 firelighters at the back of the fire cube and place
approximately 1
– 1.5kg of solid fuel onto the firelighter and set the Air Flow
Bar to setting III fully extended. Light firelighter and close door, if condensation
appears on the glass when the door is closed leave ajar. Do not leave stove
unattended when the door is open.
Summary of Contents for Alpine 4 Series
Page 1: ...1 For use in the UK and ROI NT27 October 2013 www chesneys co uk ...
Page 11: ...11 Milan 4 Passive Figure 1 ...
Page 12: ...12 Figure 1 Fitters notes ...
Page 13: ...13 Apollo 8 Dimensions Apollo 4 Dimension ...
Page 33: ...33 Riddling lever illustrated with the red arrow below Air flow bar Air Flow Bar Settings ...
Page 45: ...45 Annual Service Record Date Company Name Signature Notes ...