Chimney Connection
1) Drop the liner through the outer casing and fix the flue adaptor,
then fit the flue collar to the adaptor bending the adaptor lugs to
secure the collar to the adaptor.
2) On the 8 series only there is an additional directional flue collar
that bolts to the inside of the outer casing. This will need to be
done at this stage.
Note:
If connecting to an existing chimney you will need to make an opening
in the front face of the chimney breast above the outer casing to make a
compliant appropriate connection to the outer casing flue collar and the
existing flue.
3) Slide the fire cube back into the outer casing and fix in place with
two fixing bolts as previously illustrated.
4) Secure the flue collar inside the fire cube, ensuring a good seal is
achieved.
5) Replace all internal parts starting with the second baffle.
Hearth
The Apollo range must be installed on a full constructional hearth in
accordance with Building Regulations, Document J section 2 dia 26 & 27,
All hearths for all appliances must be secured and level.