38
The Baffle By-pass can be adjusted by undoing the M6 nut and rotating the
baffle actuation rod in or out, then retighten the M6 nut. Close the door and
check the position of the Baffle By-pass, it should fit flush to the main baffle
when the stove is cold. The Baffle by-pass will not fit flush with the main baffle
when the stove is under fire.
The baffle must be removed completely before sweeping through the stove,
do not sweep the flue though the baffle by-pass.
The vermiculite floor, side, rear and baffle are consumable these will need to
be replaced as required.
To remove these consumables:
1. Lift out the log retainer.
2. Remove the floor bricks (3 in number).
3. Remove the steel u shaped brick support.
4. Remove the by-pass baffle (refer to page 4).
5. Fold in one side brick taking the weight of the main baffle.
6. Fold in the other side brick and remove the main baffle.
7. The two side bricks can now be removed.
To replace simply reverse the above instructions.
Summary of Contents for Alpine 4 Series
Page 1: ...1 For use in the UK and ROI NT27 October 2013 www chesneys co uk ...
Page 11: ...11 Milan 4 Passive Figure 1 ...
Page 12: ...12 Figure 1 Fitters notes ...
Page 13: ...13 Apollo 8 Dimensions Apollo 4 Dimension ...
Page 33: ...33 Riddling lever illustrated with the red arrow below Air flow bar Air Flow Bar Settings ...
Page 45: ...45 Annual Service Record Date Company Name Signature Notes ...