31
12. First Lighting and Operation
This appliance is not to be used as an incinerator. Only HETAS approved
wood logs and smokeless fuels are recommended by Chesneys for use in this
appliance.
This appliance is design to operate with the door closed, except for lighting
and reloading, failure to close the door during operation will result in fume
spillage.
Warning Note:
Properly installed, operated and maintained this appliance will not emit
fumes into the dwelling. Occasional fumes from de-ashing and re-
fuelling may occur. However, persistent fume emission is potentially
dangerous and must not be tolerated. If fume emission does persist, the
following immediate actions should be taken:-
Open doors and windows to ventilate room then leave the premises
Let the fire out or eject and safely dispose of fuel from the appliance.
Check for flue or chimney blockage, and clean if required.
Do not attempt to relight the fire until the cause of the fume emission
has been identified and corrected. If necessary seek expert advice.
Your installer should have fitted a CO alarm in the same room as the
appliance. If the alarm sounds unexpectedly, follow the instructions
given under “Warning Note” above.
Note
Before lighting please note the following points:
Chesneys stoves must only use HETAS approved wood fuels and smokeless
coal.
Do not use any liquid fuels.
Do not over load your stove.
Never empty the ash when the fire is alight.
Do not burn solid fuel and wood at the same time. Wood burns from the top
down, whereas solid fuel burns from the bottom up, therefore there is a
conflict of air supply for complete combustion of your fuel.
The fuel selector must always be either wood or solid fuel. Do not set half
way.
Always use the glove provided to operate the handle and controls.
This appliance will get very hot and fireguards must be used where
appropriate.
Summary of Contents for Alpine 4 Series
Page 1: ...1 For use in the UK and ROI NT27 October 2013 www chesneys co uk ...
Page 11: ...11 Milan 4 Passive Figure 1 ...
Page 12: ...12 Figure 1 Fitters notes ...
Page 13: ...13 Apollo 8 Dimensions Apollo 4 Dimension ...
Page 33: ...33 Riddling lever illustrated with the red arrow below Air flow bar Air Flow Bar Settings ...
Page 45: ...45 Annual Service Record Date Company Name Signature Notes ...