27
Door Seal Testing and Adjustment
Without a good sound airtight seal around the door the stove will not work as
designed and will lead to the glass blackening and a loss of control.
Over time the rope seal compresses and the seal between the door and the
fire cube is compromised resulting in the need to replace the rope.
Testing the door seal
With the stove cold take a piece of paper, open the door and place the paper
between the door and the stove. Close the door. The paper should be trapped
between the door and the fire cube. There should be some resistance when
pulling the paper out. This should be done on all four sides of the door.
Adjusting the door
Where the paper is not trapped the door needs to be adjusted. If the
adjustment needs to be made on the handle side of the stove, wind or unwind
the handle one complete turn and retest. For appliances that have a restricted
90 degree handle, release the grub screw on the side of the door boss (figure
4) to allow the mechanism to turn fully. Replace after adjustment. If the handle
does not line up with the door simply screw the grub screw in or out until it
does.
Figure 4
For adjustments on the hinge side of the stove the door must be removed. Lift
the top off the stove, twist and rest on the fire cube. Open the door
(Shoreditch, Shipton, Salisbury and Beaumont models) and lift from the hinge
pins.
Loosen the grub screws under the hinge pins, rotate hinge pin in clockwise
direction to reduce the gap between the door and fire cube, anticlockwise to
increase the gap. Replace door and check seal before tightening grub screws.
Summary of Contents for Alpine 4 Series
Page 1: ...1 For use in the UK and ROI NT27 October 2013 www chesneys co uk ...
Page 11: ...11 Milan 4 Passive Figure 1 ...
Page 12: ...12 Figure 1 Fitters notes ...
Page 13: ...13 Apollo 8 Dimensions Apollo 4 Dimension ...
Page 33: ...33 Riddling lever illustrated with the red arrow below Air flow bar Air Flow Bar Settings ...
Page 45: ...45 Annual Service Record Date Company Name Signature Notes ...