Multi-Fuel 6 Series
Parameters
Wood / Ancit
Beaumont
Belgravia
Shoreditch
Salisbury
Shipton
Alpine
Milan
Nominal heat output
kW
7.0 / 6.0
6.2 / 6.0
6.2 / 6.7
Mean CO emission (at 13 %
0
2)
0.34 / 0.37
0.34 / 0.37
0.3 / 0.23
Mean flue Gas temperature oC
265 / 199
324 / 294
324 / 294
Flue gas mass flow
g/s
3.7 / 4.1
5.4 / 4.1
5.4 / 3.7
Total efficiency Nett
%
Gross %
85.1 / 80.4
77.4/78.8
85.1 / 80
77.4/78.4
85.1 / 80.4
77.4/78.8
Refuelling
mins
45 / 150
45 / 150
60 / 60
Test fuel wood / ancit Kg
1.5 / 2.1
1.5 / 2.1
2.09 / 2.1
Fuel 2 x logs mm 13-14 % moisture
Ancit per 2.1kg 2.3 % moisture
300 x 150
dia
300 x 150
dia
300 x 150
dia
Maximum hearth temp
oC
56.1
56
55
to log store
Dimensions / Weight
Refer to Figure one on Page 8
A
mm
B
mm
C
mm
D
mm
E
mm
Weight
kg
Beaumont
704
522
155
541
395
128
Belgravia
704
522
155
541
395
120
Shoreditch
685
448
155
531
393
120
Shoreditch LS
803
448
155
648
393
132
Shoreditch XLS
903
448
155
748
393
139
Salisbury
653
450
155
505
440
123
Shipton
634
488
155
480
395
131
Alpine
686
460
140
523
386
125
Milan
920
525
195
740
472
127
Milan and Shoreditch LS and XLS can be installed with skirting boards
50mm from rear of the stove to a maximum height of 200mm
The chimney and connecting fluepipe must have a minimum diameter of 150
mm and its dimension should not narrow to less than the size of the outlet
socket of the stove at any point.
Minimum Flue Draught 12 Pascal
Summary of Contents for Alpine 4 Series
Page 1: ...1 For use in the UK and ROI NT27 October 2013 www chesneys co uk ...
Page 11: ...11 Milan 4 Passive Figure 1 ...
Page 12: ...12 Figure 1 Fitters notes ...
Page 13: ...13 Apollo 8 Dimensions Apollo 4 Dimension ...
Page 33: ...33 Riddling lever illustrated with the red arrow below Air flow bar Air Flow Bar Settings ...
Page 45: ...45 Annual Service Record Date Company Name Signature Notes ...