Dynamic HPC Threshold
This register sets the threshold for dynamic pixel correction
Address
:
0x0430
Data (11:0)
:
<value> - 0 to 4095 counts
Data (31:12)
:
N/A
3.3.22 Flat Field Correction and FPN Correction
Flat Field Correction Enable
This Register enables Flat Field Correction
Address
:
0x0420
Data (0)
:
0 – disable
1 – enable
Data (31:1)
:
N/A
Flat Field Correction
This Register selects either the Factory default FFC or the User’s custom FFC
Address
:
0x0434
Data (0)
:
0 – FFC Factory
1 – FFC User
Data (31:1)
:
N/A
FPN Correction
This register disables column Fixed Pattern Noise Correction allowing the user to
implement a custom FPN solution.
Address
:
0x0440
Data (0)
:
0 – disable
1 – enable
Data (31:1)
:
N/A