3.3.15 Strobe Control Registers
These registers enable and control the position and pulse width of the two
available strobes. The strobe signal is mapped to one or both of the available
strobe outputs.
Strobe 1 Enable
This register enables Strobe 1
Address
:
0x0630
Data (0)
:
00 – disable
01 – enable
Data (31:1)
:
N/A
Strobe 1 Reference Select
This register sets the reference for the strobe 1 Start.
Address
:
0x0634
Data (0)
:
0 – Exposure Start
1 – Readout Start
Data (31:1)
:
N/A
Strobe 1 Delay
This register sets the strobe 1 delay from the selected Reference.
Address
:
0x0638
Data (19:0)
:
<value> – delay in micro sec., 1 sec max.
Data (31:20)
:
N/A
Strobe 1 Width
This register sets the strobe 1 pulse duration.
Address
:
0x063C
Data (19:0)
:
<value> –width in micro sec., 1 sec max.
Data (31:20)
:
N/A
Strobe 2 Enable
This register enables Strobe 2
Address
:
0x0640
Data (0)
:
00 – disable
01 – enable
Data (31:1)
:
N/A