CHEETAH Hardware User’s Manual
Imperx, Inc.
Rev. 1.6
6421 Congress Ave.
8/26/2016
Boca Raton, FL 33487
+1 (561) 989-0006
61 of 121
camera should automatically load itself following a power cycle or receipt of a
reset (
‘SW_Reset’
) command.
3.2.2.1 Boot From
This register determines which configuration space (factory, user#1 or user
#2) should be loaded into the camera following a power cycle or reset
(
‘SW_Reset’
) command. Upon a power cycle or reset, the camera reads the
‘boot from’ value from non-volatile memory and loads the appropriate
configuration space.
Address
:
0x6000
Data (1- 0)
:
00 – Boot from Factory
01 – Boot from User #1
:
10 – Boot from User #2
Data (31- 2)
:
N/A
3.3.2.2 Load From Factory
The
‘Load From Factory’
command instructs the camera to load its
workspace from the factory space. All current workspace settings will be
replaced with the contents of the factory space. This is a command, not a
register. The act of writing to this location initiates the load from the factory.
Address
:
0x6060
3.3.2.3 Load From User #1
The
‘Load From User #1’
command instructs the camera to load its
workspace from the user #1 space. All current workspace settings will be
replaced with the contents of the user #1 space. This is a command, not a
register. The act of writing to this location initiates the load from the user #1.
Address
:
0x6064
3.3.2.4 Load From User #2
The
‘Load From User #2’
command instructs the camera to load its
workspace from the user #2 space. All current workspace settings will be
replaced with the contents of the user #2 space. This is a command, not a
register. The act of writing to this location initiates the load from the user #2.
Address
:
0x6068