8
Water Tight Conduit
(Not provided)
NOTE:
Power and control
wiring MUST be run in
separate conduits.
Operator
Earth Ground Rod
Check national and local
codes for proper depth
Warning Sign
Warning Sign
Photoelectric
Sensors
Edge Sensor
Edge Sensor
Operator
Operator
Water Tight Conduit
(Not provided)
NOTE:
Power and control wiring
MUST be run in separate conduits.
Earth Ground Rod
Check national and local
codes for proper depth
Warning Sign
Photoelectric
Sensors
Edge Sensors
INTRODUCTION
OVERVIEW OF TYPICAL INSTALLATION
SINGLE GATE
DUAL GATE
Identify your installation type (refer to the Appendix in the back of the manual for more information).
NOTE:
One or more non-contact sensors
shall be located where the risk of
entrapment or obstruction exists at either
the opening or closing direction. Care shall
be exercised to reduce the risk of nuisance
tripping, such as when a vehicle, trips the
sensor while the gate is still moving.