42
once
F
a
c
to
ry
s
e
tt
in
g
DISPLAY
ACTION
CONFIGURATION
x times
Section
Digit 1
Digit 2
Digits 3 and 4
Continuous pump run
4
0
0
: Yes
1
: No
Pump overrun duration
4
2
0
to
5
min by step
0.5 min
4
3
Maximum Central Heating flow
temperature
4
4
50°C
to
80°C
by steps of 1
o
C
Minimum Central Heating flow
temperature
4
5
25°C
to
50°C
by steps of 1
o
C
4
6
CH anti-cycling delay
4
8
0
to
7
min by step
0.5 min
CH maximum output limitation
4
9
Value from
0
to
10
Pmin & Pmax general
Menu - 4 - Boiler settings