28
-
If a remote time clock is to be fitted, using a volt-free switching time clock, remove the link wire and connect the
switching wires from the time clock following the points opposite above (see also
Diagram B Fig. 33
).
-
If using an external time clock and room thermostat, remove the link wire and connect in series as above (see also
Diagram C Fig. 33
).
Live and Neutral connections to operate the clock motor must be taken from a suitable source.
Connector
11 (Fig. 32)
, is provided for connecting an optional integral time clock or programmer, for fitting instructions, please
refer to those provided with the clock or page 28 of this manual.
Fig. 33
C
ONNECTOR
12
ON
PCB,
SEE
F
IG
. 32
13. Electrical Connections
(continued)
C
ONNECTOR
12
ON
PCB,
SEE
F
IG
. 32
C
ONNECTOR
12
ON
PCB,
SEE
F
IG
. 32