18.3.9 Removing the water pressure switch
1.
Carry out steps
18.1.1 and 18.3.1
;
2.
Pull off the connections and remove the pressure
switch by releasing it’s securing clip
(see Fig. 98)
.
Fig. 98
18.3.8 Removing the pressure gauge
1.
Carry out steps
18.3.1 and 18.3.3
;
2.
Remove the pressure gauge by releasing the two
clips
V
and pulling the pressure gauge out. (
see
Fig. 97
)
Fig. 97
V
18.4
Access to the Control System
18.4.1 Removing the P.C.B.s
Fig. 99
Fig. 100
Fig. 101
Fig. 102
W2
W1
W3
3.
Release the three clips
W2
and remove the
electrical box cover (s
ee Fig. 100)
;
1.
Carry out steps
18.1.1
and
18.1.2
;
2.
Remove the screw
W1
from the electrical box (
see
Fig. 99
);
5.
Remove all electrical connections from the display
PCB (see
Fig. 101
);
4.
Remove the two screws
W3
from the front control
panel and lower the front control panel (see
Fig.
101
);