BIT0: SDR Log
BIT1: Max. Log
BIT2: Min. Log
BIT3: EN50160
Others: Reserved
40826~40833
RW
FTP User name
char
40834~40841
RW
FTP Password
char
40842
RW
Login FTP with Anonymous
uint16
0= Enabled, 1= Disabled
0
40843
RW
FTP Visible
uint16
0= Enabled, 1= Disabled
0
40844
RW
TELNET Visible
uint16
0= Enabled, 1= Disabled
0
Table 5-65 System Setup Parameters
Notes:
1)
The following table lists the Codes for different Time Zones.
Code
Time Zone
Code
Time Zone
Code
Time Zone
0
GMT-12:00
11
GMT-2:00
22
GMT+5:45
1
GMT-11:00
12
GMT-1:00
23
GMT+6:00
2
GMT-10:00
13
GMT-0:00
24
GMT+6:30
3
GMT-9:00
14
GMT+1:00
25
GMT+7:00
4
GMT-8:00
15
GMT+2:00
26
GMT+8:00
5
GMT-7:00
16
GMT+3:00
27
GMT+9:00
6
GMT-6:00
17
GMT+3:30
28
GMT+9:30
7
GMT-5:00
18
GMT+4:00
29
GMT+10:00
8
GMT-4:00
19
GMT+4:30
30
GMT+11:00
9
GMT-3:30
20
GMT+5:00
31
GMT+12:00
10
GMT-3:00
21
GMT+5:30
32
GMT+13:00
Table 5-66 Time Zones
2)
The timestamp of historical data is programmable which is illustrates below:
0: local time
1: UTC time
BIT
Description
Note
BIT0
MODBUS
Timestamp of retrived Data log via Modbus: Real-time measurement, Device/PQLOG,
SDR, Real-time measurements, Max./Min. log, Plt/Pst
BIT1
COMTRADE
Timestamp of COMTRADE file and the first/trigger point in .cfg file
BIT2
PQDIF
Timestamp of PQDIF file, file name and store directory.
Table 5-67 Timestamp of Historical Data
3)
0 means the DWR file doesn’t involve sampling section information.
5.9 Time Registers
There are two sets of
Time
registers supported by the PMC-690 - Year / Month / Day / Hour / Minute /
Second (Registers # 60000 to 60002 for 6-digit addressing and Registers # 9000 to 9002 for 5-digit
addressing) and UNIX Time (Registers # 60004 to 600005 for 6-digit addressing and Registers # 9004 to
9005 for 5-digit addressing). When sending time to the PMC-690 over Modbus communications, care
should be taken to only write one of the two Time register sets. All registers within a Time register set
must be written in a single transaction. If registers 60000 to 60004 (or 9000 to 9004 for 5-digit
addressing) are being written to at the same time, both Time register sets will be updated to reflect the
new time specified in the UNIX Time register set 60004 (9004) where the time specified in registers
60000 to 60003 (9000-9003 for 5-digit addressing) will be ignored. Writing to the Millisecond register
60003 (9003 for 5-digit addressing) is optional during a Time Set operation. When broadcasting time,
the function code must be set to 0x10 (Pre-set Multiple Registers). Incorrect date or time values will be
rejected by the meter.
Register
Property
Description
Format
Note
6-digit
5-digit
60000
9000
RW
High-order Byte: Year
UINT16
0-37 (Year-2000)
Low-order Byte: Month
1 to 12
Summary of Contents for PMC-690
Page 1: ...PMC 690 Hand Held Power Quality Analyzer User Manual Version V1 0A Aug 27 2018...
Page 21: ...CET Electric Technology 21 Energy Demand Harmonics Spectrum Table Power...
Page 23: ...CET Electric Technology 23 Max Min Setup Basic Device Storage...
Page 24: ...CET Electric Technology 24 Advanced...
Page 26: ...CET Electric Technology 26 Monitoring History Table 3 2 Description of each Hierarchy...