© Cesab
5 – 29
T Code(s): 841, 842, 843
Repair manual: Parameters
Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040
Date: 2018-05-01
Applies from serial number: 6384351-
Parameters #1003-1042
Factory parameters # 1003 to 1042 - configurable optional functions
Parameters #1003 to #1042 are reserved in the truck’s control system for
extra truck options and/or special product modifications. The parameters
configure and control the Spider expansion unit (SEU) that must be fitted to
the truck, in some cases it is enough to have an empty I/0 in the motor control.
This method of implementation enables use of the standard program. This
eliminates the need for any special program.
Normally, these parameters are configured by the manufacturer when the
truck is modified or customised. It is advisable to upload the parameter
settings from the truck when carrying out any modification. If the main control
unit [A2] has been replaced, the original parameter settings can be
transferred to the new unit, thus ensuring that special options function
correctly.
Factory parameter no. #1003, #1008, #1013, #1018, #1023, #1028, #1033
and #1038 can be adjusted to allow up to a maximum of 8 pre-programmed
"Basic options" to be activated and configured to suit a specific special option
or customisation.
Activation of optional functions
The system can use up to eight configurable optional functions
simultaneously. Each configurable function is controlled by five factory
parameters. During activation, an index parameter (#1003, #1008, #1013,
#1018, #1023, #1028, #1033, #1038) must first be set to a value equivalent
to an optional function. Four parameters that can be modified to configure the
optional function are linked to each index parameter.
•
The index parameter is allocated one optional function (optional function is
determined).
•
Each optional function can have up to 4 arguments associated with it.
Each argument holds a value which can be changed to configure the
function (optional function is configured).
•
If the value of an argument is outside of the highest or lowest permitted
value, an error code is generated and the option cannot be used.
The error code cannot be eliminated until the argument is given a
permissible value.