13.2 Removing the tiller arm
1.
Remove the inspection cover.
2.
Remove the cover (T).
3.
Unscrew the retaining screws of the yoke (R).
4.
Detach the cable clamp (P) by pressing on the clamp with your thumbs
and lifting it upwards. Pull the cable clamp out through the hole in the
steering console.
Note:
Do not try to prise away the cable clamp with a screwdriver.
5.
Cut off the cable ties of the cable duct on the transistor regulator side and
disconnect cable connections X5 and X65.
Install in reverse order.
13.3 Replacing an gas strut
1.
Remove the cover (T).
2.
Remove the cable clamp retaining screw (W)
3.
Unscrew the adjusting screw (Q).
4.
Remove the locking mechanism (E) from the gas strut lock shaft (C)
5.
Detach the gas strut lock shaft (C).
6.
Remove the gas strut.
Install in reverse order.
Note:
Pay attention during assembly and make sure no cables are pinched.