© Cesab
8 – 38
T Code(s): 841, 842, 843
Repair manual: Troubleshooting
Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040
Date: 2018-05-01
Applies from serial number: 6384351-
8:024
T14 has reduced
the charging
current to 0A
because of high
temperature.
Not influenced
1:
Cooling
is
reduced or the
temperature
sensor
is
defective.
1:
Check the cooling
•
Check the cooling flanges of the
transistor regulator, motor and
steering motor as well as the
battery charger and fans and
filters for accumulations of dirt
and dust. Too much dust and dirt
cause the cooling not to work
properly.
•
Check that the fans work when
the speed control is activated
(fans behind T1 and motor fan)
•
Check that the fan on charger
T14 works when the charging
starts, i.e. when the mains cable
is connected
•
Check the signal from the
temperature sensors for T1 and
T13 and from B1 using the
integrated test or TruckCom.
Determine if the temperature
signals are plausible relative to
the real temperatures of the
components. If not, replace
T1,T13 or replace B1 with a
repair kit.
8:027
Internal error in
T14
Not influenced
1:
No
software
compatibility
2:
Defective
component
1:
Update the truck software
•
Update the truck software to the
latest version.
2:
Replace the T14
8:028
The main charging
time is exceeded
by 5-11 hours
depending of
battery capacity.
Not influenced
1:
Battery
parameters
109 and 110
incorrectly set.
2:
The battery is
defective
1:
Check parameters
•
Check that factory parameters
are set according to the truck
configuration.
•
Check that other parameters
are set correctly.
2:
Check the battery.
Code
Description
Truck
behaviour
Error cause(s)
Procedure