Parameter 111 - Reset procedure after collision (option)
#111 - Reset procedure after collision
Specifies the condition for how the truck is to be taken into operation again
after the collision sensors have been triggered.
The PIN code to be activated for resetting can be found in operator profile 1
and special block 10. Page 6–4
Parameter 112 - Clear application data
#112 - Clear application data
Specifies whether information from the histogram/collision sensor is to be
deleted at login.
The histogram data consists of the logged motor temperature, motor control and
steering motor in the form of a histogram. You clear this data by setting parameter
112 =1. This is useful when transferring the truck from one client to another.
The collision log is a log with the 10 latest collisions are stored together with the
operator PIN code. You clear this data by setting parameter 112 =2.
Par.
Description
Min.
Defa
ult
Max.
Incre
ment
Unit
111
Resetting procedure after
collision
0
0
3
1
Value
Function
0
Function not activated
1
The operator can reset the truck.
2
Horn sounds once every five seconds.
3
Options 1 and 2 combined.
Par.
Description
Min.
Defa
ult
Max.
Incre
ment
Unit
112
Erase application data
0
0
2
1
Value
Function
0
Do not clear
1
Clear histogram at start-up
2
Clear collision log at start-up