C.E.S. Model SDI-50 Manual, Level Adjustments
6.4.5 Cali Limit Timer (*1 4)
This timer controls the maximum duration of the interconnected call.
Time out will be preceded with double warning beeps once every two
seconds. The time out warning is sent 20 seconds before the actual
time out. After the interconnect has timed out the Time Out Message
is sent. The time out timer can be reset by the mobile operator if the
software switch *5-13 is turned on. This timer is programmed in 10
second steps up to a total of 21 minutes, by entering a 3 digit
multiplier.
Example: To program the Call Limit Timer to three minutes enter
the following sequence (18 X 10 seconds = 3 minutes):
*1 (tone) 4 (tone) 018 (tone)
6.4.6 Mobile Activity Timer (*1 5)
This timer is used to disconnect the interconnect and unkey the
transmitter if the mobile should drive out of rango, or go off the
air. Each time the mobile transmits, the Mobile Activity Timer is
reset. Actual time out is preceded with single warning tones, once
every two seconds for ten seconds prior to time out. This function is
programmed in 1 second steps up to a total of 4 minutes, by entering a
3 digit multiplier.
Example: Program the activity timer for 30 seconds:
*1 (tone) 5 (tone) 030 (tone)
6.4.7 Station Identification Interval (*1 6)
This Program Code determines how often the Station ID Message is
transmitted automatically; but if desired the call sign could be
programmed into any message location. The time is entered as multiples
of 10 seconds.
Example: To set the Station ID timer for 10 minutes:
*1 (tone) 6 (tone) 060 (tone)
Page # 24